Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
06845 | RAYTHEON COMPANY DBA RAYTHEON |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRBZ | WINDING OPERATING CURRENT | 10.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY |
ADAT | BODY WIDTH | 0.625 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD |
ADAU | BODY HEIGHT | 0.547 INCHES NOMINAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAQ | BODY LENGTH | 0.625 INCHES NOMINAL |
CBME | CUBIC MEASURE (NON-CORE) | 0.2 CUBIC INCHES |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 30.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
AARD | DUMMY TERMINAL QUANTITY (NON-CORE) | 2 |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | OPEN |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 8.30 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |