Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
SWITCH , WAVEGUIDE

Definition:

AN ITEM SPECIFICALLY DESIGNED FOR MECHANICALLY OR ELECTRONICALLY POSITIONING ONE OR MORE WAVEGUIDE SECTIONS SO AS TO COUPLE IT OR THEM TO OTHER SECTIONS IN A WAVEGUIDE SYSTEM. THE SWITCHING FUNCTION MAY BE OPERATED BY A MANUAL ACTUATOR, AN ELECTROMECHANICAL ACTUATOR OR BY MEANS OF AN ARRANGEMENT OF SEMICONDUCTORS AND PASSIVE CIRCUIT DEVICES. EXCLUDES RELAY, (AS MODIFIED).

CAGE Information

Code Company
01456 MICROWAVE DEVELOPMENT LABORATORIES I

Federal Supply Class

Title

ANTENNAS, WAVEGUIDES, AND RELATE

Inclusions:

INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.

Exclusions:

EXCLUDES TOWER STRUCTURES.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ABHP OVERALL LENGTH 9.500 INCHES NOMINAL
AKNV MINIMUM CROSSTALK RATING IN DECIBELS 60.0 SINGLE
AKPJ ACTUATOR VOLTAGE IN VOLTS 50.0 NOMINAL
CQJX NOMINAL THREAD SIZE 0.190 INCHES MOUNTING FACILITY HOLE
ABKW OVERALL HEIGHT 3.940 INCHES NOMINAL
FEAT SPECIAL FEATURES DIODE JAN 1N4246 INSTALLED ACROSS SOLENOID LEADS
AFGA OPERATING TEMP RANGE -0.0/+55.0 DEG CELSIUS
AKPT WAVEGUIDE FLANGE TYPE COVER
AKPE ACTUATOR CURRENT TYPE AND RATING IN AMPS 1.3 DC MAXIMUM
CQJX NOMINAL THREAD SIZE 0.190 INCHES FLANGE CONNECTION FACILITY HOLE
THSD THREAD SERIES DESIGNATOR UNF MOUNTING FACILITY HOLE
ABMK OVERALL WIDTH 5.150 INCHES NOMINAL
AKPC ACTUATOR OPERATING METHOD RELAY
THSD THREAD SERIES DESIGNATOR UNF FLANGE CONNECTION FACILITY HOLE
AKPP SWITCHING TIME 100.0 MILLISECONDS
AKPQ SWITCH RETURN MECHANISM TYPE FAIL-SAFE
AKNF RF POWER HANDLING CAPABILITY 80.0 KILOWATTS PEAK 2ND
AKNF RF POWER HANDLING CAPABILITY 2.5 KILOWATTS AVERAGE 1ST
CSQT FLANGE CONNECTING FACILITY AND QUANTITY 24 THREADED HOLE

Similar Parts

20-5334P1 , 205334P1 , 5985-01-155-2042 , 5985011552042 , 011552042