Part Number
Definition:
A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
95266 | OECO LLC DBA PACIFIC SCINTIFIC OECO |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
THSD | THREAD SERIES DESIGNATOR | UNEF SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED BUSHING SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
ABHP | OVERALL LENGTH | 5.125 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.250 INCHES MAXIMUM |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY INPUT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES SINGLE GROUP |
CRMJ | WINDING POWER RATING | 840.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE PRIMARY INPUT |
ADAR | BODY OUTSIDE DIAMETER | 1.375 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 0.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 28.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
TTQY | TERMINAL TYPE AND QUANTITY | 5 TAB, SOLDER LUG |