Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
33469 | AVIONICS COMMUNICATIONS SYSTEMS INC |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
MATT | MATERIAL | PLASTIC BOARD |
MATT | MATERIAL | PLASTIC BOARD |
AMPS | CURRENT RATING IN AMPS | 30.0 |
AAMA | MOUNTING HOLE DIAMETER | 0.219 INCHES |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 1.312 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.875 INCHES |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 12 SINGLE |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 7.875 INCHES |
ABGS | BASE THICKNESS | 0.375 INCHES |
CWLN | TERMINAL DESIGN | NONFEEDTHRU |
ABGQ | BOARD OVERALL HEIGHT | 1.312 INCHES |
CRNL | NONFEEDTHRU TERMINAL TYPE | 857 SINGLE |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.188 INCHES |
ABGP | BOARD OVERALL WIDTH | 2.000 INCHES |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 1.000 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.625 INCHES |
AAQL | BODY STYLE | BARRIER TYPE |
ABGN | BOARD OVERALL LENGTH | 8.250 INCHES |