Part Number
Part Number:
NSN:
NIIN:
Item Name:
REGULATOR , ENGINE GENERATOR
Definition:
A REGULATOR DESIGNED TO AUTOMATICALLY MAINTAIN THE CURRENT AND/OR VOLTAGE OUTPUT OF AN ENGINE GENERATOR WITHIN SPECIFIED LIMITS, REGARDLESS OF VARIATION OF LOAD OR INPUT VOLTAGES. MAY INCLUDE CUTOUT RELAY. DOES NOT INCLUDE ITEMS IN WHICH REGULATION IS ACCOMPLISHED BY TRANSFORMER ACTION. SEE ALSO REGULATOR, CURRENT AND REGULATOR, VOLTAGE.
CAGE Information
Code | Company |
---|---|
29510 | KOMATSU AMERICAN INTL CO |
Federal Supply Class
Title
ENGINE ELECTRICAL SYSTEM COMPONE
Inclusions:
INCLUDES GENERATORS; MAGNETOS; SPARK PLUGS; IGNITION COILS; IGNITION DISTRIBUTORS; ENGINE VOLTAGE REGULATORS; IGNITION HARNESS ASSEMBLIES; STARTING MOTORS FOR ENGINES.
Exclusions:
EXCLUDES VEHICULAR LIGHTING FIXTURES (FSC 6220) AND AIRCRAFT GENERATORS (FSC 2925).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ANYX | CUTOUT VOLTAGE RATING | NOT RATED |
ANYD | SYSTEM GROUND POLARITY | NEGATIVE |
APAK | CENTER TO CENTER DISTANCE BETWEEN HOLES ALONG WIDTH AND HOLE ALONG LENGTH | 5.075 NOMINAL CENTIMETERS |
ADNZ | DISTANCE BETWEEN HOLES ALONG WIDTH | 1.485 INCHES MINIMUM |
ANYC | SYSTEM VOLTAGE RATING | 12.0 |
AARB | TERMINAL TYPE | CONNECTOR, RECEPTACLE W/INTERNAL CONTACTS |
ANYD | SYSTEM GROUND POLARITY | POSITIVE |
ANYH | VOLTAGE REGULATOR UNIT QUANTITY | 1 |
ADNZ | DISTANCE BETWEEN HOLES ALONG WIDTH | 1.515 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.282 NOMINAL CENTIMETERS |
ABTB | MOUNTING HOLE DIAMETER | 0.272 NOMINAL MILS |
ANPP | OUTPUT VOLTAGE RATING IN VOLTS | 14.3 MAXIMUM |
ANZB | REVERSE CURRENT OVERLOAD CIRCUIT BREAKER | NOT INCLUDED |
ANYR | CIRCUIT CONTROL DEVICE TYPE | SOLID STATE CIRCUIT BOARD |
ANYE | VOLTAGE REGULATOR UNIT TYPE | TRANSISTOR |
ADER | MOUNTING STYLE | THREE HOLE TRIANGULAR |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT |
AGBC | SHOCK MOUNT | NOT PROVIDED |
ANYZ | CUTOUT CURRENT RATING IN AMPS | NOT RATED |
ANZF | CONDUIT CONNECTION QUANTITY | 1 |
ALBH | RADIO INTERFERENCE SHIELDING | NOT PROVIDED |
ANZC | FIELD RELAY UNIT | NOT INCLUDED |
ANPP | OUTPUT VOLTAGE RATING IN VOLTS | 13.7 MINIMUM |
ANYS | CUT-IN VOLTAGE RATING | NOT RATED |
AARA | TERMINAL QUANTITY | 3 |
ADZC | ENVIRONMENTAL PROTECTION | WATERTIGHT |
APAK | CENTER TO CENTER DISTANCE BETWEEN HOLES ALONG WIDTH AND HOLE ALONG LENGTH | 5.045 NOMINAL MILS |
ANZE | TERMINAL ENCASEMENT | ENCASED |