Part Number
Part Number:
NSN:
NIIN:
Item Name:
INSULATION SLEEVING , ELECTRICAL , S
Definition:
A RIGID OR FLEXIBLE TUBING HAVING OTHER THAN UNIFORM FABRICATED SHAPES OR FORMS. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS OR BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE ITEMS. EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; AND INSULATION SLEEVING, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
06090 | TYCO ELECTRONICS CORPORATION DIV RAY |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
HUES | COLOR | BLACK |
HUES | COLOR | BLACK |
ADZC | ENVIRONMENTAL PROTECTION | FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT |
STYL | STYLE DESIGNATOR | BOOT-STRAIGHT-LONG |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 200.0 VOLTS PER MIL /0.001 INCH/ |
CQBC | MINIMUM TENSILE STRENGTH | 600 POUNDS PER SQUARE INCH |
FLEX | FLEXIBILITY | FLEXIBLE |
ABJH | TEMP RATING | -75.0 DEG CELSIUS AND 250.0 DEG CELSIUS |
AGAJ | MAIN BODY SMALL END INSIDE DIAMETER | 0.230 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AGAJ | MAIN BODY SMALL END INSIDE DIAMETER | 0.400 INCHES MINIMUM AS SUPPLIED |
AGAB | MAIN BODY WALL THICKNESS | 0.080 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAL | DISTANCE FROM BOTTOM OF SHOULDER TO LARGE END OF MAIN BODY | 0.620 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAH | MAIN BODY OVERALL LENGTH | 5.000 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
MATL | MATERIAL | RUBBER,SILICONE,RT-602,RAYCHEM CORP |
AGAK | MAIN BODY LARGE END INSIDE DIAMETER | 0.880 INCHES MINIMUM AS SUPPLIED |
AGAK | MAIN BODY LARGE END INSIDE DIAMETER | 0.620 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |