Part Number
Part Number:
NSN:
NIIN:
Item Name:
INSULATION SLEEVING , ELECTRICAL , S
Definition:
A RIGID OR FLEXIBLE TUBING HAVING OTHER THAN UNIFORM FABRICATED SHAPES OR FORMS. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS OR BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE ITEMS. EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; AND INSULATION SLEEVING, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
K0720 | HELLERMANNTYTON LIMITED |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AGAR | ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 10.0 NOMINAL AS SUPPLIED |
AGAR | ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 10.0 NOMINAL AS SUPPLIED |
AGAA | DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 1.700 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
HUES | COLOR | BLACK |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 200.0 VOLTS PER MIL /0.001 INCH/ |
AGAR | ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 22.5 NOMINAL AFTER UNRESTRICTED RECOVERY |
ADZC | ENVIRONMENTAL PROTECTION | MILDEW RESISTANT AND FLAME RESISTANT AND CORROSION RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT |
AFZW | SECOND BRANCH INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
AGAC | FIRST BRANCH WALL THICKNESS | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAB | MAIN BODY WALL THICKNESS | 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
MATL | MATERIAL | PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP |
AGAG | DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 1.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AFZU | MAIN BODY INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
STYL | STYLE DESIGNATOR | TRANSITION-Y |
CQBC | MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
AGAD | SECOND BRANCH WALL THICKNESS | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AFZW | SECOND BRANCH INSIDE DIAMETER | 0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZV | FIRST BRANCH INSIDE DIAMETER | 0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
FLEX | FLEXIBILITY | SEMIRIGID |
AFZU | MAIN BODY INSIDE DIAMETER | 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZV | FIRST BRANCH INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
ABJH | TEMP RATING | -55.0 DEG CELSIUS |