CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
81541 SENSATA TECHNOLOGIES MARYLAND INC

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.595 INCHES MINIMUM AND 0.655 INCHES MAXIMUM
TTQY TERMINAL TYPE AND QUANTITY 6 TAB, SOLDER LUG
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRX ACTUATOR POSITION DESIGNATION AT POLE TWO
AKPX POLE QUANTITY 3
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 7.5 AMPERES AC ALL LOCATIONS
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS AND 0.009 MINIMUM AT 500 PCT ALL LOCATIONS AND 0.070 MINIMUM AT 300 PCT ALL LOCATIONS AND 0.300 MAXIMUM AT 300 PCT ALL LOCATIONS AND 0.500 MINIMUM AT 200 PCT ALL LOCATIONS AND 0.900 MAXIMUM AT 500 PCT ALL LOCATIONS
ADAQ BODY LENGTH 1.970 INCHES MINIMUM AND 2.030 INCHES MAXIMUM
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
ADAT BODY WIDTH 1.915 INCHES MINIMUM AND 1.945 INCHES MAXIMUM
AJEC BOSS HEIGHT 0.095 INCHES MINIMUM AND 0.125 INCHES MAXIMUM
ADAU BODY HEIGHT 1.740 INCHES MINIMUM AND 1.770 INCHES MAXIMUM
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT
ADTV CASE MATERIAL PLASTIC
CPRQ RESET METHOD MANUAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 CLIP
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
CPRW ACTUATOR FUNCTION TRIP-RESET
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
CPRP ULTIMATE TRIP TIME PER POLE IN SECONDS 2.000 MINIMUM ALL LOCATIONS AND 60.000 MAXIMUM ALL LOCATIONS
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC SINGLE LOCATION