Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
81541 SENSATA TECHNOLOGIES MARYLAND INC

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE ANY ACCEPTABLE SECOND LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 24.0 DC SECOND LOCATION
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS AND 1000.0 DC ALL LOCATIONS
ADAU BODY HEIGHT 1.555 INCHES MAXIMUM
AKPX POLE QUANTITY 2
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP FIRST LOCATION
ADAQ BODY LENGTH 2.000 INCHES NOMINAL
CPRX ACTUATOR POSITION DESIGNATION BETWEEN POLE ONE AND TWO
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.500 MINIMUM AT 200 PCT FIRST LOCATION AND 9.000 MAXIMUM AT 200 PCT FIRST LOCATION
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 CLIP
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT
ADTV CASE MATERIAL PLASTIC
CPRQ RESET METHOD MANUAL
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.050 MAXIMUM AT 200 PCT SECOND LOCATION AND 0.025 MAXIMUM AT 300 PCT SECOND LOCATION
AJEC BOSS HEIGHT 0.125 INCHES NOMINAL
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 15.0 AMPERES AC FIRST LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 120.0 AC FIRST LOCATION
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
ADAT BODY WIDTH 1.540 INCHES NOMINAL
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
TTQY TERMINAL TYPE AND QUANTITY 6 QUICK DISCONNECT, MALE
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.625 INCHES NOMINAL
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
CPSM INTERNAL TRIP RELEASE CONFIGURATION RELAY TRIP SECOND LOCATION
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
FREQ FREQUENCY IN HERTZ 50.0 FIRST LOCATION OR 60.0 FIRST LOCATION

Similar Parts