Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
81541 |
SENSATA TECHNOLOGIES MARYLAND INC |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
2 TOGGLE |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 DC SINGLE LOCATION |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
ADAQ |
BODY LENGTH |
2.000 INCHES NOMINAL |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
0.050 MINIMUM AT 200 PCT SINGLE LOCATION AND 0.950 MAXIMUM AT 200 PCT SINGLE LOCATION |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC SINGLE LOCATION |
ADAU |
BODY HEIGHT |
1.770 INCHES NOMINAL |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 CLIP |
PKWT |
UNPACKAGED UNIT WEIGHT |
2.100 OUNCES |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
FUNGUS RESISTANT |
ADTV |
CASE MATERIAL |
PLASTIC |
AKPX |
POLE QUANTITY |
1 |
CPRQ |
RESET METHOD |
MANUAL |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
2.5 AMPERES DC SINGLE LOCATION |
AJEC |
BOSS HEIGHT |
0.125 INCHES NOMINAL |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
50.0 DC SINGLE LOCATION |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 QUICK DISCONNECT, MALE |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 SINGLE LOCATION |
ADAT |
BODY WIDTH |
1.695 INCHES NOMINAL |