Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
81541 |
SENSATA TECHNOLOGIES MARYLAND INC |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
EXTERNAL AT POLE ONE |
ADAT |
BODY WIDTH |
0.920 INCHES NOMINAL |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC SINGLE LOCATION |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 DC SINGLE LOCATION |
CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 ALARM |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 TAB, SOLDER LUG |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
ADAU |
BODY HEIGHT |
1.770 INCHES MAXIMUM |
ADAQ |
BODY LENGTH |
2.000 INCHES NOMINAL |
FEAT |
SPECIAL FEATURES |
FLUSH MTG HARDWARE INCL; ILLUMINATED HANDLE |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPRP |
ULTIMATE TRIP TIME PER POLE IN SECONDS |
0.200 MINIMUM SINGLE LOCATION AND 7.000 MAXIMUM SINGLE LOCATION |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 CLIP |
AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
ADTV |
CASE MATERIAL |
PLASTIC |
AKPX |
POLE QUANTITY |
1 |
CPRQ |
RESET METHOD |
MANUAL |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
2.5 AMPERES DC SINGLE LOCATION |
AJEC |
BOSS HEIGHT |
0.125 INCHES NOMINAL |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
50.0 DC SINGLE LOCATION |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
0.020 MINIMUM AT 400 PCT SINGLE LOCATION AND 0.050 MINIMUM AT 200 PCT SINGLE LOCATION AND 0.950 MAXIMUM AT 200 PCT SINGLE LOCATION AND 0.240 MAXIMUM AT 400 PCT SINGLE LOCATION |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
CRTK |
SWITCH TERMINAL TYPE |
TURRET |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
3.0 DC |
CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
50.0 DC |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 SINGLE LOCATION |