Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
81541 SENSATA TECHNOLOGIES MARYLAND INC

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CQQR THREAD PITCH IN MILLIMETERS 0.50
FREQ FREQUENCY IN HERTZ 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS
AJEC BOSS HEIGHT 0.150 INCHES NOMINAL
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
AKPX POLE QUANTITY 3
CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
THSD THREAD SERIES DESIGNATOR ISO M
CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 250.0 AC AND 50.0 DC
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CQJX NOMINAL THREAD SIZE 3.0 MILLIMETERS
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.060 INCHES NOMINAL
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 5.0 AMPERES AC ALL LOCATIONS
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES NOMINAL
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.475 INCHES NOMINAL
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS PROOF AND MOISTURE RESISTANT AND SALT WATER RESISTANT
ADAT BODY WIDTH 2.265 INCHES NOMINAL
AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 10.0 AC AND 3.0 DC
ADTV CASE MATERIAL PLASTIC
CPRQ RESET METHOD MANUAL
CPRP ULTIMATE TRIP TIME PER POLE IN SECONDS 0.040 MAXIMUM ALL LOCATIONS
AXHR MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
CRTK SWITCH TERMINAL TYPE TAB, SOLDER LUG
CQSM SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE THREE
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 2100.0 AC ALL LOCATIONS
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 120.0 AC ALL LOCATIONS
CBBL FEATURES PROVIDED HIGH INRUSH PROTECTION
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
TTQY TERMINAL TYPE AND QUANTITY 6 THREADED STUD
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS
ADAQ BODY LENGTH 2.490 INCHES NOMINAL
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.940 INCHES NOMINAL
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 1000.0 ALL LOCATIONS
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.750 INCHES NOMINAL

Similar Parts

205-111-1REC2-62F-3-502-AMO , 2051111REC262F3502AMO , 5925-01-175-9296 , 5925011759296 , 011759296