CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
81541 SENSATA TECHNOLOGIES MARYLAND INC

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
BBRJ SPECIAL HANDLING FEATURE MAGNETIC
FREQ FREQUENCY IN HERTZ 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS
AJEC BOSS HEIGHT 0.150 INCHES NOMINAL
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 20.0 AMPERES AC ALL LOCATIONS
AKPX POLE QUANTITY 3
CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 250.0 AC AND 50.0 DC
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED SHOCKPROOF AND CORROSION RESISTANT AND MOISTURE RESISTANT AND VIBRATIONPROOF AND FUNGUS RESISTANT
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC ALL LOCATIONS
ADAT BODY WIDTH 2.265 INCHES MAXIMUM
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
PKWT UNPACKAGED UNIT WEIGHT 11.100 OUNCES
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.625 INCHES MAXIMUM
CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 10.0 AC AND 3.0 DC
ADTV CASE MATERIAL PLASTIC
CPRQ RESET METHOD MANUAL
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CRTK SWITCH TERMINAL TYPE QUICK DISCONNECT, MALE
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
THSD THREAD SERIES DESIGNATOR UNC
AXHR MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
ADAQ BODY LENGTH 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 120.0 AC ALL LOCATIONS
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
TTQY TERMINAL TYPE AND QUANTITY 6 THREADED STUD
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.940 INCHES NOMINAL
CMLP THREAD QUANTITY PER INCH 32
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
CQSM SWITCH LOCATION AND POSITION DESIGNATION INTERNAL BETWEEN POLE ONE AND TWO
CQJX NOMINAL THREAD SIZE 0.138 INCHES