FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
ADAT |
BODY WIDTH |
2.250 INCHES MAXIMUM |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
EXTERNAL AT POLE ONE |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 AC ALL LOCATIONS |
AJEC |
BOSS HEIGHT |
0.150 INCHES NOMINAL |
AKPX |
POLE QUANTITY |
3 |
CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 ALARM |
CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE, TWO, AND THREE LINKED |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.750 INCHES MAXIMUM |
CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
10.0 AC |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
3 TOGGLE |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.060 INCHES NOMINAL |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
5.0 AMPERES AC ALL LOCATIONS |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.506 INCHES MAXIMUM |
CBBL |
FEATURES PROVIDED |
SLIDING BAR INTERLOCK |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
ADTV |
CASE MATERIAL |
PLASTIC |
CPRQ |
RESET METHOD |
MANUAL |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
20.000 MAXIMUM AT 200 PCT ALL LOCATIONS AND 0.400 MINIMUM AT 400 PCT ALL LOCATIONS AND 3.200 MAXIMUM AT 400 PCT ALL LOCATIONS AND 0.012 MINIMUM AT 600 PCT ALL LOCATIONS AND 2.200 MINIMUM AT 200 PCT ALL LOCATIONS AND 0.200 MAXIMUM AT 600 PCT ALL LOCATIONS |
FEAT |
SPECIAL FEATURES |
BLACK HANDLE |
THSD |
THREAD SERIES DESIGNATOR |
UNC |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
6 THREADED HOLE |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC ALL LOCATIONS |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
DUSTPROOF AND FUNGUS PROOF AND MOISTURE RESISTANT AND SALT SPRAY PROOF |
CRTK |
SWITCH TERMINAL TYPE |
TAB, SOLDER LUG |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.750 INCHES MAXIMUM |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
250.0 AC |
TTQY |
TERMINAL TYPE AND QUANTITY |
6 THREADED STUD |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
150.0 ALL LOCATIONS |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC ALL LOCATIONS |
CPRP |
ULTIMATE TRIP TIME PER POLE IN SECONDS |
5.000 MINIMUM ALL LOCATIONS AND 60.000 MAXIMUM ALL LOCATIONS |
ADAQ |
BODY LENGTH |
2.490 INCHES NOMINAL |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.940 INCHES NOMINAL |
CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |