Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
28527 ITT CORPORATION

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
AKDX WINDING QUANTITY 1
AAJD THREAD CLASS 2A SINGLE MOUNTING FACILITY
THSD THREAD SERIES DESIGNATOR UNC SINGLE MOUNTING FACILITY
CSQJ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE 1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 110.0 AC AND 26.5 DC
APCN COIL QUANTITY 1
CQYJ MOUNTING FACILITY PATTERN TRIANGLE SINGLE MOUNTING FACILITY
AYSC PILE-UP MAIN CONTACT FORM ARRANGEMENT 4A1B
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 26.5 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING
CRPQ NOMINAL OPERATING CURRENT RATING AND TYPE 30.0 MILLIAMPERES DC SINGLE WINDING
CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE MOUNTING FACILITY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 0.938 INCHES NOMINAL SINGLE MOUNTING FACILITY
AXHR MOUNTING FACILITY TYPE AND QUANTITY 3 THREADED STUD SINGLE MOUNTING FACILITY
ADZC ENVIRONMENTAL PROTECTION HERMETIC
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 1.0 AMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD
APNP DUTY TYPE CONTINUOUS
ABMK OVERALL WIDTH 1.400 INCHES NOMINAL
APNA WINDING DC RESISTANCE RATING 2.8 KILOHMS NOMINAL SINGLE WINDING
ABHP OVERALL LENGTH 1.590 INCHES NOMINAL
ABKW OVERALL HEIGHT 2.060 INCHES NOMINAL