Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
K1384 |
RACAL RADAR DEFENCE SYSTEMS LTD |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.672 INCHES MINIMUM AND 1.732 INCHES MAXIMUM |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 TAB, SOLDER LUG |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
CQJX |
NOMINAL THREAD SIZE |
0.500 INCHES |
THSD |
THREAD SERIES DESIGNATOR |
UN |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC SINGLE LOCATION |
ADTV |
CASE MATERIAL |
PLASTIC |
AKPX |
POLE QUANTITY |
1 |
CPRQ |
RESET METHOD |
MANUAL |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
50.0 DC SINGLE LOCATION |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
5.0 AMPERES DC SINGLE LOCATION |
AJEC |
BOSS HEIGHT |
0.058 INCHES MINIMUM AND 0.078 INCHES MAXIMUM |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |