Part Number
Definition:
AN ELECTRICAL FITTING WITH ELECTRICAL CONTACTS CONSTRUCTED TO BE AFFIXED TO THE END OF A CABLE, CONDUIT, COAXIAL LINE, CORD, WIRE (INCLUDES PRINTED/ETCHED), PRINTED WIRING BOARD, OR THE LIKE FOR CONVENIENCE IN JOINING WITH ANOTHER ELECTRICAL CONNECTOR(S) OR PRINTED WIRING BOARD. IT IS DESIGNED TO BE MOUNTED ON A BULKHEAD, CHASSIS, PANEL, WALL, PRINTED WIRING BOARD, OR THE LIKE. EXCLUDES LAMPHOLDER; JACK, TELEPHONE; JACK, TIP; INSERT ELECTRICAL CONNECTOR; INSERT MODULE, ELECTRICAL CONNECTOR; CONNECTOR BODY (AS MODIFIED) AND SOCKET, PLUG-IN ELECTRONIC COMPONENTS. SEE ALSO WIRING HARNESS (AS MODIFIED) AND CABLE ASSEMBLY (AS MODIFIED). FOR ITEMS WITH TERMINATION WIRES OF MORE THAN FOUR INCHES IN LENGTH, SEE LEAD ASSEMBLY, ELECTRICAL. FOR ITEMS WITHOUT INSERTS, SEE SHELL, ELECTRICAL CONNECTOR.
CAGE Information
Code | Company |
---|---|
24446 | GENERAL ELECTRIC CO |
Federal Supply Class
Title
CONNECTORS, ELECTRICAL
Inclusions:
INCLUDES PLUGS; JACKS; RECEPTACLES, ELECTRONIC COMPONENT SOCKETS AND ASSOCIATED ACCESSORIES
Exclusions:
EXCLUDES INTERCONNECTORS, FIBER OPTIC
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKW | OVERALL HEIGHT | 0.938 INCHES NOMINAL |
AFQX | CONTACT POSITION ARRANGEMENT STYLE | 2 SINGLE MATING END |
AFRE | CONTACT MAXIMUM DC VOLTAGE RATING IN VOLTS | 125.0 SINGLE MATING END 1ST CONTACT GROUPING |
AAQL | BODY STYLE | STRAIGHT SHAPE |
CQZG | INSERT MATERIAL | RUBBER SINGLE MATING END |
AFQW | MATING END QUANTITY | 1 |
CSCF | TERMINAL TYPE | SCREW SINGLE MATING END ALL CONTACT GROUPINGS |
ABMK | OVERALL WIDTH | 1.250 INCHES NOMINAL |
AFRE | CONTACT MAXIMUM DC VOLTAGE RATING IN VOLTS | 250.0 SINGLE MATING END 2ND CONTACT GROUPING |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.126 INCHES MINIMUM AND 0.134 INCHES MAXIMUM |
AFRC | CONTACT MAXIMUM CURRENT RATING IN AMPS | 15.0 SINGLE MATING END 1ST CONTACT GROUPING |
CSPT | SHELL MATERIAL | IRON |
ABHP | OVERALL LENGTH | 1.875 INCHES NOMINAL |
CQTM | TERMINAL LOCATION | BACK SINGLE MATING END ALL CONTACT GROUPINGS |
AFRT | SHELL TYPE | SOLID |
AFRD | CONTACT MAXIMUM AC VOLTAGE RATING IN VOLTS | 125.0 SINGLE MATING END 1ST CONTACT GROUPING |
AFRN | POLARIZATION METHOD | CONTACT |
AGAV | END ITEM IDENTIFICATION | BOLIERS, 1200 PSI; INTEGRATED LAUNCH & RECOVERY TV SURVEILLANCE SYS (ILARTS); VIRGINIA CLASS CGN (41); SPRUANCE CLASS DD (963); FORRESTAL CLASS CV; MK 38 GUN FIRE CONTROL SYSTEM; TICONDEROGA CLASS CG (47); HELICOPTER, ADVANCE ATTACK, AH-1W |
CXCL | INCLUDED CONTACT TYPE | FLAT SOCKET SINGLE MATING END ALL CONTACT GROUPINGS |
AFRC | CONTACT MAXIMUM CURRENT RATING IN AMPS | 10.0 SINGLE MATING END 2ND CONTACT GROUPING |
CXCG | INCLUDED CONTACT QUANTITY | 1 SINGLE MATING END 1ST CONTACT GROUPING |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
AFRD | CONTACT MAXIMUM AC VOLTAGE RATING IN VOLTS | 150.0 SINGLE MATING END 2ND CONTACT GROUPING |
AFQZ | CONTACT REMOVABILITY | NONREMOVABLE SINGLE MATING END ALL CONTACT GROUPINGS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.500 INCHES NOMINAL |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CXCG | INCLUDED CONTACT QUANTITY | 1 SINGLE MATING END 2ND CONTACT GROUPING |