Part Number
Definition:
AN ITEM HAVING EITHER A SINGLE TAPPED WINDING (AUTOTRANSFORMER TYPE), OR TWO OR MORE WINDINGS DESIGNED TO FURNISH INDUCTIVE REACTANCE AND/OR TRANSFER ELECTRICAL ENERGY IN CIRCUITS BY MEANS OF A MAGNETIC FIELD. IT IS SO DESIGNED THAT ITS ENTIRE INTENDED RANGE OF OPERATIONS IS ABOVE 20 KILOHERTZ (KILOCYCLES). THE MINIMUM VALUE MAY EXTEND INTO THE AUDIO FREQUENCY RANGE (BELOW 20 KILOHERTZ). IT MAY INCLUDE INTEGRAL CAPACITORS, COILS, RESISTORS, AND ADJUSTABLE TUNING CORES. FOR ITEMS HAVING ONLY TWO ACTIVE TERMINALS SEE COIL, RADIO FREQUENCY. INCLUDES TYPES HAVING WINDINGS WHICH MAY BE MOVED WITH RESPECT TO EACH OTHER. EXCLUDES TRANSFORMER, DISCRIMINATOR.
CAGE Information
Code | Company |
---|---|
13499 | ROCKWELL COLLINS INC. DBA GOVERNMENT |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED SINGLE COMPONENT |
ACZP | COIL FORM TYPE | SOLID SINGLE COMPONENT |
ADAU | BODY HEIGHT | 1.122 INCHES MINIMUM AND 1.138 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ADAT | BODY WIDTH | 0.552 INCHES MINIMUM AND 0.568 INCHES MAXIMUM |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
ABHY | TURN QUANTITY | 4 SINGLE COMPONENT SINGLE SECONDARY |
ADAQ | BODY LENGTH | 1.105 INCHES MINIMUM AND 1.155 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 5 WIRE LEAD |
ABHY | TURN QUANTITY | 2 SINGLE COMPONENT SINGLE PRIMARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.02535 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE PRIMARY |
BKPL | RATING METHOD | WINDING TURNS SINGLE COMPONENT SINGLE PRIMARY |
BKPL | RATING METHOD | WINDING TURNS SINGLE COMPONENT SINGLE SECONDARY |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
CBBL | FEATURES PROVIDED | COLOR CODED LEAD |
CQPZ | WINDING CONDUCTOR SIZE | 0.02535 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE SECONDARY |