Part Number
Part Number:
NSN:
NIIN:
Item Name:
WAVEGUIDE ASSEMBLY
Definition:
AN ITEM CONSISTING OF ONE OR MORE DEFINITE LENGTHS OF STRAIGHT OR FORMED, FLEXIBLE OR RIGID, PREFABRICATED HOLLOW TUBING OF CONDUCTIVE MATERIAL. THE TUBING HAS A PREDETERMINED CROSS SECTION AND IS DESIGNED TO GUIDE OR CONDUCT HIGH FREQUENCY ELECTROMAGNETIC ENERGY THROUGH ITS INTERIOR. ONE OR MORE ENDS ARE TERMINATED. MAY INCLUDE COMMON MOUNTING OF A SWITCH, WAVE GUIDE, A DUMMY LOAD, ELECTRICAL AND OTHER COMPONENTS SUCH AS WAVEGUIDE SECTION, CABLE TERMINAL CHAMBER AND THE LIKE. EXCLUDES COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; AND TUNER, WAVEGUIDE.
CAGE Information
Code | Company |
---|---|
54647 | MICROTECH INC. |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
PRMT | PRECIOUS MATERIAL | SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
AHSF | FLANGE QUANTITY | 2 |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM ALL FLANGES AND 0.453 INCHES MAXIMUM ALL FLANGES |
SFTT | SURFACE TREATMENT | SILVER ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
PMLC | PRECIOUS MATERIAL AND LOCATION | ALL SURFACES SILVER |
AHSZ | FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM ALL FLANGES AND 1.890 INCHES MAXIMUM ALL FLANGES |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM ALL FLANGES ALL CONNECTION FACILITIES AND 0.172 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | COVER TYPE ALL FLANGES |
MATT | MATERIAL | COPPER ALLOY ALL TUBING SEGMENT AND FLANGE |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSY | FLANGE INSIDE HEIGHT | 0.628 NOMINAL MILS ALL FLANGES AND 0.631 NOMINAL CENTIMETERS ALL FLANGES |
AHTA | FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM ALL FLANGES AND 1.890 INCHES MAXIMUM ALL FLANGES |
FEAT | SPECIAL FEATURES | PROTECT FLANGES WITH PLASTIC COVERS; STENCIL "DO NOT KINK" ON WAVEGUIDE SURFACE |
AHSX | FLANGE INSIDE WIDTH | 1.253 INCHES MINIMUM ALL FLANGES AND 1.256 INCHES MAXIMUM ALL FLANGES |
AHSE | TUBING MANUFACTURER PART NUMBER (NON-CORE) | ERR-070 |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.08 |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
AHTR | FLANGE MANUFACTURER PART NUMBER (NON-CORE) | ERR-070 |
FLEX | FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
CXBB | WAVEGUIDE CENTER TO CENTER DISTANCE | 4.970 INCHES MINIMUM AND 5.030 INCHES MAXIMUM |
CRFH | WAVEGUIDE INSIDE WIDTH | 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM |
STYL | STYLE DESIGNATOR | OFFSET BEND TYPE |
CQGM | MAXIMUM OPERATING PRESSURE | 5.0 POUNDS PER SQUARE INCH GAGE |
AFJN | FRAGILITY FACTOR (NON-CORE) | MODERATELY RUGGED |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
CTFD | WAVEGUIDE LENGTH | 14.720 INCHES MINIMUM AND 14.780 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM |