Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
02640 | MAGNETIKA |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.407 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.469 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-WYE |
ADAQ | BODY LENGTH | 3.813 INCHES MINIMUM AND 3.938 INCHES MAXIMUM |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
ADAU | BODY HEIGHT | 5.062 INCHES MINIMUM AND 5.250 INCHES MAXIMUM |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 199.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/NEUTRAL TAP SINGLE COMPONENT SINGLE SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.969 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.031 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 54.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 11 PIN |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
ABKW | OVERALL HEIGHT | 5.875 INCHES MAXIMUM |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ADAT | BODY WIDTH | 3.250 INCHES MINIMUM AND 3.375 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |