Part Number
Definition:
A SPECIFIC ELECTRICAL ELEMENT OR SET OF ELECTRICAL ELEMENTS THAT ARE CONNECTED TOGETHER TO FORM A FIXED ARRANGEMENT AND USED AS A SUBSTITUTE LOAD FOR TERMINATING AN ELECTRICAL CIRCUIT. A DUMMY LOAD CONTAINS ALL THE ESSENTIAL ELECTRICAL CHARACTERISTICS NECESSARY TO TERMINATE THE CIRCUIT BUT DOES NOT FUNCTION IN THE SAME MANNER AS THE LOAD WHICH IT REPLACES. EXAMPLES ARE RESISTORS USED TO REPLACE ANTENNAS, BATTERIES, LOUDSPEAKERS, OR THE LIKE. INCLUDES SINGLE PORT TERMINATIONS OF TWIN LEAD, COAXIAL AND WAVEGUIDE TRANSMISSION LINES AS LOW POWER TERMINATIONS OF A SECTION OF A TRANSMISSION SYSTEM IN A SPECIFIED MANNER. INCLUDES DUMMY LOADS WHEN ARRANGED IN A GROUP OR BANK. EXCLUDES POWER ABSORBERS. SEE ALSO LOAD BANK, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
34078 | EMERSON NETWORK POWER CONNECTIVITY S |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKRZ | TERMINATION TYPE | CONNECTION COAXIAL |
ARNH | OPERATING POSITION | ALL POSITIONS |
AKNK | VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE | +0.000/+8.000 GIGAHERTZ AND +8.000/+18.000 GIGAHERTZ |
STYL | STYLE DESIGNATOR | COAXIAL MOUNTED |
ACYW | IMPEDANCE RATING IN OHMS | 50.0 NOMINAL |
BFMF | COOLING METHOD | SELF-COOLED |
AGAV | END ITEM IDENTIFICATION | AN/MLQ-34 |
AHUD | CONNECTOR END DESIGN | MALE |
AHUC | COAXIAL CONNECTOR SERIES DESIGNATION | TNC |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
ABHP | OVERALL LENGTH | 0.770 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 0.630 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.440 INCHES NOMINAL |
AFGQ | FREQUENCY RANGE RATING | +0.000/+18.000 GIGAHERTZ |
AJDB | POWER RATING | 2.000 WATTS PEAK |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.20 AND 1.25 |