Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
11873 MCGRAW EDISON CO USD OPNS SUB OF COO

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
CXCY PART NAME ASSIGNED BY CONTROLLING AGENCY CIRCUIT BREAKER
FEAT SPECIAL FEATURES SERIES 21X MINI CIRCUIT BREAKERS, TYPE 1, 14VDC
AGAV END ITEM IDENTIFICATION NSN 2320-01-447-6345 CHASSIS, TRUCK. W/S FAMILY OF MEDIUM TACHICAL VEHICLES
ADTV CASE MATERIAL PLASTIC
AKPX POLE QUANTITY 1
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 15.0 DC SINGLE LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 14.0 DC SINGLE LOCATION
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 15.0 AMPERES DC SINGLE LOCATION
TTQY TERMINAL TYPE AND QUANTITY 2 QUICK DISCONNECT, MALE
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 TERMINAL

Similar Parts

21115-00 , 2111500 , 5925-01-525-0948 , 5925015250948 , 015250948