Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
81844 ELECTRONIC CONTROLS CORPORATION

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 28.0 DC
AKDX WINDING QUANTITY 1
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 0.56 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.147 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABMK OVERALL WIDTH 2.320 INCHES NOMINAL
APCN COIL QUANTITY 1
CQYJ MOUNTING FACILITY PATTERN TRIANGLE SINGLE MOUNTING FACILITY
ABHP OVERALL LENGTH 2.750 INCHES NOMINAL
CSQJ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY
AXHR MOUNTING FACILITY TYPE AND QUANTITY 3 UNTHREADED HOLE SINGLE MOUNTING FACILITY
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES DC RESISTIVE LOAD
AJSS FREQUENCY IN HERTZ 400.0 NOMINAL
APNP DUTY TYPE CONTINUOUS
ABKW OVERALL HEIGHT 2.030 INCHES NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 4 PIN ALL FUNCTIONS
AYSC PILE-UP MAIN CONTACT FORM ARRANGEMENT 1A

Similar Parts