Part Number
Part Number:
NSN:
NIIN:
Item Name:
MOTOR , CONTROL
Definition:
A MOTOR WHICH IS DESIGNED TO BE OPERATED FROM TWO INDEPENDENT VOLTAGE SOURCES, IN SUCH A WAY THAT VARIATIONS IN ONE VOLTAGE SOURCE WILL DETERMINE THE DIRECTION AND SPEED OF THE MOTOR. IN THE ALTERNATING CURRENT TYPE THE VOLTAGES ARE USUALLY APPLIED TO A SPLIT-PHASE STATOR, WHEREAS IN THE DIRECT CURRENT TYPE, ONE VOLTAGE IS APPLIED TO THE STATOR AND THE OTHER TO THE ARMATURE. LOW INERTIA AND RAPID REVERSIBILITY ARE INHERENT CHARACTERISTICS OF THIS TYPE OF MOTOR. SEE ALSO SERVOMOTOR, AUTOMATIC PILOT.
CAGE Information
Code | Company |
---|---|
80064 | NAVAL SHIP SYSTEMS COMMAND |
Federal Supply Class
Title
MOTORS, ELECTRICAL
Inclusions:
Exclusions:
EXCLUDES STARTING MOTORS FOR ENGINES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CWDY | TEMP RATING | 60.0 AMBIENT DEG CELSIUS |
CWDY | TEMP RATING | 60.0 AMBIENT DEG CELSIUS |
CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 115.0 LINE TO NEUTRAL SINGLE INPUT |
ANPZ | INCLOSURE FEATURE | TOTALLY INCLOSED |
AXGY | MOUNTING METHOD | END BELL |
CWFX | ROTOR SPEED RATING IN RPM | 3450.0 SINGLE NO LOAD |
ABGH | STEP DIAMETER | 0.470 INCHES NOMINAL SINGLE END |
BKPQ | INCLOSURE SPECIFICATION | COMMERCIAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD |
BFMF | COOLING METHOD | AMBIENT AIR |
CWGL | CURRENT RATING IN AMPS | 0.110 SINGLE INPUT |
AAJV | OVERALL WIDTH | 8.000 INCHES |
AAJT | OVERALL HEIGHT | 8.875 INCHES |
ACDC | CURRENT TYPE | DC INPUT |
AAJU | OVERALL LENGTH | 12.435 INCHES |
ABGJ | STEP LENGTH | 0.562 INCHES NOMINAL SINGLE END |
CWCS | LENGTH OF SHAFT FROM HOUSING | 1.812 INCHES SINGLE END |
CWFQ | MOUNTING FACILITY CIRCLE DIAMETER | 3.531 INCHES |
BKPB | CURRENT RATING METHOD | LOAD |
BFML | CONTROL FIELD WINDING TYPE | SINGLE WINDING |
ABWV | SHAFT DIAMETER | 0.6250 INCHES NOMINAL SINGLE END |
CWHZ | SHAFT END CHARACTERISTIC | A12 SINGLE STYLE SINGLE END |