Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
52090 TELEMECANIQUE INC

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
ABMK OVERALL WIDTH 3.000 INCHES NOMINAL
ABKW OVERALL HEIGHT 4.000 INCHES NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 2 SCREW ALL FUNCTIONS
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.188 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABHP OVERALL LENGTH 4.250 INCHES NOMINAL
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 4.500 INCHES NOMINAL SINGLE MOUNTING FACILITY
APCN COIL QUANTITY 1
AGAV END ITEM IDENTIFICATION APPROACH LIGHTING SYSTEM,MEDIUM INTENSITY RUNWAY (MALSR)
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 60.0 AMPERES AC RESISTIVE LOAD
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY
APNP DUTY TYPE CONTINUOUS
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 110.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 600.0 AC
CQYJ MOUNTING FACILITY PATTERN RECTANGULAR SINGLE MOUNTING FACILITY

Similar Parts

2160B621AA , 2160B621AA , 5945-01-127-2910 , 5945011272910 , 011272910