Part Number
Part Number:
NSN:
NIIN:
Item Name:
TEST SET , INSULATION BREAKDOWN
Definition:
A TEST SET PRIMARILY DESIGNED TO DETECT AND INDICATE INSULATION BREAKDOWN IN ELECTRIC MOTORS, TRANSFORMERS, AND THE LIKE, AT SPECIFIC TEST VOLTAGES. SEE ALSO TEST SET, ARMATURE; AND OHMMETER.
CAGE Information
Code | Company |
---|---|
07239 | AVO INTL |
Federal Supply Class
Title
ELECTRICAL AND ELECTRONIC PROPER
Inclusions:
INCLUDES TEST LEADS AND TEST LEAD ATTACHMENTS; TEST INSTRUMENTS DESIGNED FOR COMMUNICATION EQUIPMENT; TEST INSTRUMENTS DESIGNED FOR USE WITH ELECTRONIC EQUIPMENT CLASSIFIED IN TWO OR MORE FSC GROUPS.
Exclusions:
EXCLUDES RADIAC EQUIPMENT
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AQYL | TEST LEAD QUANTITY | 2 |
ABFY | OVERALL DEPTH | 5.000 INCHES NOMINAL |
FTLD | FUNCTIONAL DESCRIPTION | TESTS INSULATION RESISTANCE OF FUEL PUMP ASSY,SHUT-OFF VALVES OR TRANSDUCERS |
ABHP | OVERALL LENGTH | 7.000 INCHES NOMINAL |
ABCC | WIRE TERMINATION TYPE | ALLIGATOR |
AFSC | WIRE LEAD LENGTH | 120.000 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | T-46A AIRCRAFT |
APSK | SCALE RANGE | +0.0/+1000.0 MEGOHMS |
ANPN | OUTPUT CURRENT TYPE | DC |
ABMK | OVERALL WIDTH | 4.000 INCHES NOMINAL |
ZZZV | FSC APPLICATION DATA | 6625-00-643-2250,OHMMETER |
ACYR | DC VOLTAGE RATING | 500.0 VOLTS NOMINAL |