Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
81541 SENSATA TECHNOLOGIES MARYLAND INC

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AJEC BOSS HEIGHT 0.205 INCHES MINIMUM AND 0.265 INCHES MAXIMUM
BBRJ SPECIAL HANDLING FEATURE MAGNETIC
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 3.535 INCHES MINIMUM AND 3.565 INCHES MAXIMUM
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.735 INCHES MINIMUM AND 2.765 INCHES MAXIMUM
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 100.0 AMPERES AC FIRST LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 480.0 AC FIRST LOCATION
AKPX POLE QUANTITY 3
CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
PKWT UNPACKAGED UNIT WEIGHT 2.000 POUNDS
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 10.0 AC
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
TTQY TERMINAL TYPE AND QUANTITY 4 THREADED STUD
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
ADAQ BODY LENGTH 5.110 INCHES MINIMUM AND 5.140 INCHES MAXIMUM
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.100 MINIMUM AT 200 PCT FIRST LOCATION AND 0.800 MAXIMUM AT 200 PCT FIRST LOCATION
AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
ADTV CASE MATERIAL PLASTIC
CPRQ RESET METHOD MANUAL
THSD THREAD SERIES DESIGNATOR UNC
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 3.535 INCHES MINIMUM AND 3.565 INCHES MAXIMUM
AXHR MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 1.011 INCHES MINIMUM AND 1.041 INCHES MAXIMUM
CRTK SWITCH TERMINAL TYPE TAB, SOLDER LUG
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY FIRST LOCATION
CQSM SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE THREE
CPSM INTERNAL TRIP RELEASE CONFIGURATION RELAY TRIP FIRST LOCATION
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE
FEAT SPECIAL FEATURES POLE TWO AND POLE THREE ARE SWITCH ONLY
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC FIRST LOCATION
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 250.0 AC
ADAT BODY WIDTH 3.108 INCHES MAXIMUM
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 1.011 INCHES MINIMUM AND 1.041 INCHES MAXIMUM
FREQ FREQUENCY IN HERTZ 60.0 FIRST LOCATION
CMLP THREAD QUANTITY PER INCH 32
CQJX NOMINAL THREAD SIZE 0.138 INCHES

Similar Parts

219-3-5701-1 , 219357011 , 5925-01-189-5084 , 5925011895084 , 011895084