Part Number
Definition:
A SPECIFIC ELECTRICAL ELEMENT OR SET OF ELECTRICAL ELEMENTS THAT ARE CONNECTED TOGETHER TO FORM A FIXED ARRANGEMENT AND USED AS A SUBSTITUTE LOAD FOR TERMINATING AN ELECTRICAL CIRCUIT. A DUMMY LOAD CONTAINS ALL THE ESSENTIAL ELECTRICAL CHARACTERISTICS NECESSARY TO TERMINATE THE CIRCUIT BUT DOES NOT FUNCTION IN THE SAME MANNER AS THE LOAD WHICH IT REPLACES. EXAMPLES ARE RESISTORS USED TO REPLACE ANTENNAS, BATTERIES, LOUDSPEAKERS, OR THE LIKE. INCLUDES SINGLE PORT TERMINATIONS OF TWIN LEAD, COAXIAL AND WAVEGUIDE TRANSMISSION LINES AS LOW POWER TERMINATIONS OF A SECTION OF A TRANSMISSION SYSTEM IN A SPECIFIED MANNER. INCLUDES DUMMY LOADS WHEN ARRANGED IN A GROUP OR BANK. EXCLUDES POWER ABSORBERS. SEE ALSO LOAD BANK, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
53711 | NAVAL SEA SYSTEMS COMMAND |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
PRMT | PRECIOUS MATERIAL | SILVER |
PMLC | PRECIOUS MATERIAL AND LOCATION | EXTERNAL SURFACES SILVER |
ARNH | OPERATING POSITION | ALL POSITIONS |
BFMF | COOLING METHOD | SELF-COOLED |
AKNK | VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE | +10.250/+10.500 GIGAHERTZ |
AWNC | INTERNAL OPERATING PRESSURE | 12.0 POUNDS PER SQUARE INCH GAGE |
AKSA | WAVEGUIDE FLANGE DESIGNATION | UG-39/U |
ABMK | OVERALL WIDTH | 3.000 INCHES MAXIMUM |
STYL | STYLE DESIGNATOR | WAVEGUIDE MOUNTED |
ACYW | IMPEDANCE RATING IN OHMS | NOT RATED |
AJDB | POWER RATING | 600.000 WATTS AVERAGE |
AKRZ | TERMINATION TYPE | WAVEGUIDE FLANGE |
ZZZV | FSC APPLICATION DATA | RADAR EQUIPMENT |
AFGQ | FREQUENCY RANGE RATING | +10.250/+10.500 GIGAHERTZ |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.10 |
ABKW | OVERALL HEIGHT | 2.750 INCHES MAXIMUM |
ABHP | OVERALL LENGTH | 8.000 INCHES MAXIMUM |