Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSMITTER , RATE OF FLOW

Definition:

CAGE Information

Code Company
99207 GENERAL ELECTRIC COMPANY DBA GE DIV

Federal Supply Class

Title

LIQUID AND GAS FLOW, LIQUID LEVE

Inclusions:

INCLUDES LIQUID LEVEL FLOAT INSTRUMENTS; REVOLUTION COUNTERS; SPEEDOMETERS; ROTATION MEASURING INSTRUMENTS AND APPARATUS; OXYGEN FLOW INDICATORS; TACHOMETERS, INCLUDING ENGINE TACHOMETERS.

Exclusions:

EXCLUDES COMBINATION INSTRUMENTS; (FSC 6695); METEOROLOGICAL INSTRUMENTS (FSC 6660); AND AUTOMATIC CONTROL VALVES (FSG 48).

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
FEAT SPECIAL FEATURES EXTENDED RANGE WITH 20 POINT CALIBRATION; 1.5 TO 30 GALLONS/MINUTE; FLOW RATION 1:20; ACCURACY 0.25% OF READING; REPEATABILITY 0.02%; MATERIALS STAINLESS STEEL
FEAT SPECIAL FEATURES EXTENDED RANGE WITH 20 POINT CALIBRATION; 1.5 TO 30 GALLONS/MINUTE; FLOW RATION 1:20; ACCURACY 0.25% OF READING; REPEATABILITY 0.02%; MATERIALS STAINLESS STEEL
ADAV OVERALL DIAMETER 1.250 INCHES NOMINAL
AARA TERMINAL QUANTITY 4
AFLW ACTUATION METHOD MOMENTUM TYPE USING IMPELLER AND TURBINE
ABKW OVERALL HEIGHT 5.035 INCHES NOMINAL
ACZB FREQUENCY RATING 72.0 HERTZ MINIMUM AND 1440.0 HERTZ MAXIMUM
ASSD MECHANICAL CONNECTION TYPE MALE FLARED TUBE
ASSC MECHANICAL CONNECTION SIZE 3/4 IN. OD TUBE SIZE
ASSB MECHANICAL CONNECTION QUANTITY 2
ZZZV FSC APPLICATION DATA TRANSMITTER,RATE OF FLOW,EXCEPT ENGINE
AARB TERMINAL TYPE PIN CONTACTS
AMSE VOLTAGE RATING 0.030 VOLTS NOMINAL
AXGY MOUNTING METHOD THD MALE TUBE CONNECTIONS
ASKX ELECTRICAL CONNECTION QUANTITY 1
ASKZ ELECTRICAL CONNECTION IDENTIFYING NUMBER MS3102A-10SL-4P OR AN3102A-10SL-4P
BGNL MEASUREMENT RANGE 570 TO 11400 LB PER HR
ADTL ATTACHMENT FEATURE QUANTITY 2
ASKY ELECTRICAL CONNECTION CONTROLLING AGENCY AN
ACDC CURRENT TYPE AC
ABHP OVERALL LENGTH 3.250 INCHES NOMINAL
FAAZ PHASE SINGLE

Similar Parts

21C2749-021 , 21C2749021 , 6680-00-400-3845 , 6680004003845 , 004003845