Part Number
Part Number:
NSN:
NIIN:
Item Name:
RESISTOR , THERMAL
Definition:
A THERMALLY SENSITIVE RESISTOR WHOSE PRIMARY FUNCTION IS TO EXHIBIT A CHANGE IN ELECTRICAL RESISTANCE WITH A CHANGE IN BODY TEMPERATURE. ITEM MAY BE MOUNTED IN A PROBE OR HOUSING. FOR BALLAST TUBE TYPE RESISTORS, SEE RESISTOR (1), CURRENT REGULATING. EXCLUDES TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE AND TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.
CAGE Information
Code | Company |
---|---|
83186 | MEAS US LLC DBA MEASUREMENT SPECIALT |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -4.40 |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 35.5 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SURFACE CONTACT |
CQWD | ZERO POWER RESISTANCE | 100.000 OHMS |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 6.8 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
STYL | STYLE DESIGNATOR | PLAIN WASHER |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 325.0 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 15.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
ADEM | WASHER THICKNESS | 0.046 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL |
ADAR | BODY OUTSIDE DIAMETER | 0.770 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0/+10.0 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0/+10.0 ALL RESISTANCE-TEMPERATURE POINTS |
CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 790.0 |