Part Number
Definition:
A DEVICE CAPABLE OF PRODUCING HEAT FROM GAS, LIQUID FUEL, OR AN ELECTRICAL HEATING ELEMENT DESIGNED FOR PERMANENT INSTALLATION IN SHEET METAL DUCTS OF A FORCED AIR CIRCULATING SYSTEM. IT CONSISTS OF (1) A FINNED, STEEL BURNER TUBE, A COMBUSTION AIR BLOWER, A CONTROL PANEL, AND A CONSTANT LEVEL FUEL SUPPLY SYSTEM OR (2) A DEVICE HAVING A HEATING ELEMENT WHICH WHEN CONNECTED TO AN ELECTRICAL SOURCE, DIRECTLY IMPARTS HEAT. IT MAY BE PROVIDED WITH A FLANGED OUTER CASING TO FACILITATE MOUNTING IN PLANNED OR EXISTING DUCT WORK. CIRCULATION OF THE HEATED AIR IS ACHIEVED BY USE OF A BLOWER OR FAN NOT INTEGRAL WITH THE HEATING UNIT.
CAGE Information
Code | Company |
---|---|
53715 | TPI CORP |
Federal Supply Class
Title
SPACE AND WATER HEATING EQUIPMEN
Inclusions:
INCLUDES BOILERS, 15 POUNDS WSP AND UNDER (FOR BOILERS OVER 15 POUNDS WSP, SEE FSC 4410); DOMESTIC WATER STORAGE TANKS THROUGH 100 GALLON CAPACITY; FIREPLACE HEATERS; FURNACES; SPACE HEATERS; HEATING RADIATORS; IMMERSION HEATERS; WATER HEATERS, THROUGH 100 GALLON RECOVERY CAPACITY (FOR HEATERS OVER 100 GALLONS RECOVERY CAPACITY, SEE FSC 4410).
Exclusions:
EXCLUDES VEHICLE HEATERS; (FSC 2540); AIRCRAFT HEATERS (FSC 1660).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQSJ | INCLOSURE MATERIAL | ALUMINUM AND STEEL CORROSION RESISTING |
AAXX | MOUNTING TYPE | WALL RECESSED, ROOM INTERIOR |
CQXD | HEAT DELIVERY RATE | 10240.0 BRITISH THERMAL UNIT |
ABAW | HEAT OUTLET QUANTITY | 2 |
ABAZ | HEAT DIRECTING DEVICE | DIRECTIONAL GRILLE |
ALYC | OPERATING CONTROL TYPE | THERMOSTATIC |
ABAY | HEAT DISCHARGE OUTLET TYPE | STATIONARY |
ABAQ | OUTLET POSITION | 180 DEG APART |
CSGC | FUEL FEED METHOD | ANY ACCEPTABLE |
FEAT | SPECIAL FEATURES | PAINTED - BAKED BEIGE ENAMEL |
HGTH | HEIGHT | 20.750 INCHES NOMINAL |
ABGL | WIDTH | 29.125 INCHES NOMINAL |
ELEC | VOLTAGE IN VOLTS | 240.0 |
BDXJ | HEATING ELEMENT TYPE | ELECTRIC NONIMMERSION |
ABAX | HEAT DELIVERY DIRECTION | VERTICAL |
ABAM | HEAT MEDIUM TYPE | AIR |
AMPS | CURRENT RATING IN AMPS | 12.5 |
ACDC | CURRENT TYPE | AC |
AEJZ | DEPTH | 4.000 INCHES NOMINAL |