Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
72421 | SIGMA INSTRUMENTS INC FISHER-PIERCE |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AKDX | WINDING QUANTITY | 1 |
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
APCN | COIL QUANTITY | 1 |
AASA | THREAD LENGTH | 0.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNA | WINDING DC RESISTANCE RATING | 8.0 KILOHMS NOMINAL SINGLE WINDING |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 3.0 MILLIAMPERES DC SINGLE WINDING |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
ABKW | OVERALL HEIGHT | 1.750 INCHES NOMINAL |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | INERT GAS |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.000 INCHES NOMINAL |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC RESISTIVE LOAD |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |