Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
05853 | PTC TRANSFORMERS |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAQ | BODY LENGTH | 3.735 INCHES MINIMUM AND 3.765 INCHES MAXIMUM |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 42.75 AC POUNDS PER HOUR DRY SINGLE COMPONENT 1ST SECONDARY AND 47.25 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 1ST SECONDARY |
ABTD | MOUNTING SLOT WIDTH | 0.188 INCHES NOMINAL SINGLE GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ADAU | BODY HEIGHT | 3.365 INCHES MINIMUM AND 3.395 INCHES MAXIMUM |
CWJS | WINDING OPERATING VOLTAGE | 16.63 AC POUNDS PER HOUR DRY SINGLE COMPONENT 3RD SECONDARY AND 18.38 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 42.75 AC POUNDS PER HOUR DRY SINGLE COMPONENT 2ND SECONDARY AND 47.25 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 2ND SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
ADAT | BODY WIDTH | 2.795 INCHES MINIMUM AND 2.825 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.235 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.265 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
FEAT | SPECIAL FEATURES | 1PRIMARY,5 SECONDARY WINDINGS |
CWJS | WINDING OPERATING VOLTAGE | 73.15 AC POUNDS PER HOUR DRY SINGLE COMPONENT 4TH SECONDARY AND 80.85 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 4TH SECONDARY |
CBME | CUBIC MEASURE (NON-CORE) | 36.1 CUBIC INCHES |
TTQY | TERMINAL TYPE AND QUANTITY | 12 TAB, SOLDER LUG |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 7.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.295 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.325 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |