Part Number
Part Number:
NSN:
NIIN:
Item Name:
REACTOR
Definition:
A COIL OR COILS USUALLY CONSTRUCTED WITH CORES HAVING LOW MAGNETIC RELUCTANCE, WHOSE PRIMARY PURPOSE IS TO FURNISH AN INDUCTIVE IMPEDANCE IN POWER OR AUDIO FREQUENCY CIRCUIT RANGING FROM ZERO TO 20 KILOHERTZ (KILOCYCLES). INCLUDES AUDIO FREQUENCY AND POWER FILTER CHOKES, AUDIO REACTORS AND SWINGING CHOKES. DOES NOT INCLUDE TRANSFORMERS OR COILS USED ABOVE AUDIO FREQUENCY RANGE. EXCLUDES SATURABLE REACTOR. FOR REACTORS WITH AIR CORES, SEE COIL (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
97424 | AMETEK INC. DIV AEROSPACE & DEFENSE |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRBZ | WINDING OPERATING CURRENT | 400.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE WINDING |
ACZB | FREQUENCY RATING | 800.0 HERTZ NOMINAL SINGLE COMPONENT |
CBBL | FEATURES PROVIDED | COLOR CODED LEAD AND TINNED WIRE LEADS |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AKDX | WINDING QUANTITY | 1 SINGLE COMPONENT |
ACYV | INDUCTANCE RATING | 15.00 MILLIHENRIES MINIMUM SINGLE COMPONENT SINGLE WINDING |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CRGS | DC RESISTANCE RATING IN OHMS | 3.000 SINGLE COMPONENT SINGLE WINDING |
ACYF | INDUCTANCE TYPE | FIXED |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
ADAT | BODY WIDTH | 0.500 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.105 INCHES MINIMUM AND 1.135 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.120 INCHES NOMINAL SINGLE GROUP |
ABHP | OVERALL LENGTH | 1.230 INCHES MINIMUM AND 1.270 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.780 INCHES MINIMUM AND 0.810 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.995 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.005 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |