Part Number
Definition:
AN ELECTRICAL FITTING WITH ELECTRICAL CONTACTS CONSTRUCTED TO BE AFFIXED TO THE END OF A CABLE, CONDUIT, COAXIAL LINE, CORD, WIRE (INCLUDES PRINTED/ETCHED), PRINTED WIRING BOARD, OR THE LIKE FOR CONVENIENCE IN JOINING WITH ANOTHER ELECTRICAL CONNECTOR(S) OR PRINTED WIRING BOARD. IT IS DESIGNED TO BE MOUNTED ON A BULKHEAD, CHASSIS, PANEL, WALL, PRINTED WIRING BOARD, OR THE LIKE. EXCLUDES LAMPHOLDER; JACK, TELEPHONE; JACK, TIP; INSERT ELECTRICAL CONNECTOR; INSERT MODULE, ELECTRICAL CONNECTOR; CONNECTOR BODY (AS MODIFIED) AND SOCKET, PLUG-IN ELECTRONIC COMPONENTS. SEE ALSO WIRING HARNESS (AS MODIFIED) AND CABLE ASSEMBLY (AS MODIFIED). FOR ITEMS WITH TERMINATION WIRES OF MORE THAN FOUR INCHES IN LENGTH, SEE LEAD ASSEMBLY, ELECTRICAL. FOR ITEMS WITHOUT INSERTS, SEE SHELL, ELECTRICAL CONNECTOR.
CAGE Information
Code | Company |
---|---|
10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL D |
Federal Supply Class
Title
CONNECTORS, ELECTRICAL
Inclusions:
INCLUDES PLUGS; JACKS; RECEPTACLES, ELECTRONIC COMPONENT SOCKETS AND ASSOCIATED ACCESSORIES
Exclusions:
EXCLUDES INTERCONNECTORS, FIBER OPTIC
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABHP | OVERALL LENGTH | 1.531 INCHES NOMINAL |
CTBC | SHELL SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | QQ-P-416,TY 2,CL 3 FED SPEC SINGLE TREATMENT RESPONSE |
AFRE | CONTACT MAXIMUM DC VOLTAGE RATING IN VOLTS | 700.0 SINGLE MATING END ALL CONTACT GROUPINGS |
AFQR | THREADED DEVICE TYPE | COUPLING FACILITY AND MOUNTING BUSHING |
AFQK | DISTANCE FROM MOUNTING SHOULDER TO FRONT FACE | 1.156 INCHES NOMINAL |
CQZG | INSERT MATERIAL | RUBBER SINGLE MATING END |
AFQW | MATING END QUANTITY | 1 |
AAJD | THREAD CLASS | 2A AND 2A |
AFRD | CONTACT MAXIMUM AC VOLTAGE RATING IN VOLTS | 500.0 SINGLE MATING END ALL CONTACT GROUPINGS |
CSWM | SHELL SURFACE TREATMENT | CADMIUM |
CXCL | INCLUDED CONTACT TYPE | ROUND SOCKET SINGLE MATING END ALL CONTACT GROUPINGS |
CMLP | THREAD QUANTITY PER INCH | 18 AND 18 |
CQTM | TERMINAL LOCATION | BACK SINGLE MATING END ALL CONTACT GROUPINGS |
AFRC | CONTACT MAXIMUM CURRENT RATING IN AMPS | 500.0 SINGLE MATING END ALL CONTACT GROUPINGS |
AAQL | BODY STYLE | STRAIGHT SHAPE THREADED |
AFRP | INSERT POSITION IN DEG | 0.0 |
AFRT | SHELL TYPE | SOLID |
CXCJ | BUSHING ACCOMMODATION HOLE SHAPE | ROUND |
AFRN | POLARIZATION METHOD | KEYWAY OR MULTIPLE KEYWAY |
AFQZ | CONTACT REMOVABILITY | REMOVABLE SINGLE MATING END ALL CONTACT GROUPINGS |
ADAV | OVERALL DIAMETER | 1.750 INCHES NOMINAL |
AAJF | THREAD DIRECTION | RIGHT-HAND AND RIGHT-HAND |
ADZC | ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT AND MOISTURE RESISTANT AND SALT WATER RESISTANT |
CSCF | TERMINAL TYPE | CRIMP SINGLE MATING END ALL CONTACT GROUPINGS |
CSPT | SHELL MATERIAL | ALUMINUM ALLOY |
CXCG | INCLUDED CONTACT QUANTITY | 3 SINGLE MATING END 1ST CONTACT GROUPING |
CQJX | NOMINAL THREAD SIZE | 1.250 INCHES AND 1.250 INCHES |
AFQX | CONTACT POSITION ARRANGEMENT STYLE | 20-22 SINGLE MATING END |
THSD | THREAD SERIES DESIGNATOR | UNEF AND UNEF |
AFQQ | MOUNTING FACILITY THICKNESS | 0.094 INCHES MINIMUM AND 0.297 INCHES MAXIMUM |
CXCG | INCLUDED CONTACT QUANTITY | 3 SINGLE MATING END 2ND CONTACT GROUPING |
AFRV | CONNECTOR LOCKING METHOD | EXTERNALLY THREADED SHELL |