Part Number
Definition:
A MANUALLY OR POWER OPERATED VALVE HAVING THREE OR MORE PORTS. THE DIRECTION OF THE FLOW THROUGH THE VARIOUS PORTS IS CONTROLLED BY EITHER ONE OR MORE RECIPROCATING SLIDE(S) OR SPOOL(S) WITH RECESS AREAS WHICH MATE WITH PORTS IN AN INTEGRAL OR REPLACEABLE PORTED SLEEVE, OR ONE OR MORE POPPET(S). IT IS DESIGNED TO CHANGE THE DIRECTION OF FLUID FLOW FROM ONE VALVE PORT TO ANOTHER. AN OFF (NO FLOW) POSITION IS NOT A FLOW PATTERN. THE VALVE IS DESIGNED TO ACTUATE VARIOUS COMPONENTS OF A FLUID SYSTEM. A POWER OPERATED VALVE MAY HAVE A MANUAL OVERRIDE. FOR ITEMS WHICH STOP, START, OR CHANGE THE FLOW OF FLUID, SEE: VALVE, SOLENOID. EXCLUDES VALVE, PLUG. SEE ALSO SERVOVALVE, HYDRAULIC; BODY SECTION, WORKING, LINEAR DIRECTIONAL CONTROL VALVE; AND VALVE ASSEMBLY.
CAGE Information
Code | Company |
---|---|
82577 | RAYTHEON COMPANY DBA RAYTHEON |
Federal Supply Class
Title
VALVES, POWERED
Inclusions:
INCLUDES ELECTRIC MOTOR OPERATED VALVES; HYDRAULIC OPERATED VALVES; SOLENOID OPERATED VALVES.
Exclusions:
EXCLUDES ENGINE INTAKE AND EXHAUST VALVES (FSC 2990, 2815); VALVES SPECIFICALLY DESIGNED FOR USE WITH FIRE FIGHTING EQUIPMENT (FSC 4210); PLUMBING EQUIPMENT, AND THE LIKE (FSC 4540).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FEAT | SPECIAL FEATURES | 8MANUFACTURERS SUGGESTED NAME IS AZIMUTH SERVOVALVE; LENGTH 2.35 INCHES; WIDTH 1.40 INCHES, HEIGHT 1.60 INCHES; WT (DRY) 0.50 LBS; COIL RESISTANCE 58.5 TO 71.5 OHMS AT 75 DEG FEH; THIS IS A TWO-STAGE, FOUR-WAY ELECTROHYDRAULIC PRESSURE CONTROL VALVE |
AQLR | VALVE OPERATION METHOD | ELECTRIC MOTOR |
CQCJ | MAXIMUM OPERATING PRESSURE AND MEDIA FOR WHICH DESIGNED | 1500.0 POUNDS PER SQUARE INCH HYDRAULIC FLUID, PETROLEUM BASE |
ADSY | VALVE DISCHARGE FLOW RATE | 0.79 GALLONS PER MINUTE |
AGAV | END ITEM IDENTIFICATION | T.O. 9H8-14-302-3; U/O CODE A |
ADQZ | END CONNECTION QUANTITY | 3 |
CYGY | FLOW PATTERN QUANTITY | 3 |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY SOURCE CONTROL DRAWING |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT AND AGAV |
CRWH | MAXIMUM OPERATING TEMP AND MEDIA FOR WHICH DESIGNED | 290.0 DEG FAHRENHEIT HYDRAULIC FLUID, PETROLEUM BASE |