Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
SWITCH , THERMOSTATIC

Definition:

A SWITCH THAT IS ACTUATED BY CHANGES IN AMBIENT TEMPERATURE. EXCLUDES CIRCUIT BREAKER; CONTROL, TEMPERATURE (AS MODIFIED); FUSE (AS MODIFIED); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; AND THERMOSTAT, FLOW CONTROL. SEE ALSO CONTROL, TEMPERATURE (AS MODIFIED) AND REGULATOR, TEMPERATURE (AS MODIFIED).

CAGE Information

Code Company
01359 FAIRCHILD CONTROLS CORPORATION

Federal Supply Class

Title

SWITCHES

Inclusions:

INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.

Exclusions:

EXCLUDES SWITCHGEAR.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CTHF CONTACT LOAD CURRENT RATING 5.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE
CTZB CONTACT VOLTAGE RATING IN VOLTS 30.0 AC AT SEA LEVEL THIRD VOLTAGE
CTHF CONTACT LOAD CURRENT RATING 5.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE
ADAU BODY HEIGHT 0.308 INCHES MINIMUM AND 0.327 INCHES MAXIMUM
FREQ FREQUENCY IN HERTZ 60.0 FIRST VOLTAGE
CTYX CONTACT STIMULUS RATING 270.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 300.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT
CSCF TERMINAL TYPE TAB, SOLDER LUG
CTZB CONTACT VOLTAGE RATING IN VOLTS 125.0 AC AT SEA LEVEL SECOND VOLTAGE
CTHF CONTACT LOAD CURRENT RATING 2.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
ABHP OVERALL LENGTH 1.050 INCHES NOMINAL
CTYC CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CQGB CONTACT ACTION STIMULUS INCREASE
MEDA MEDIA FOR WHICH DESIGNED GAS OR LIQUID
AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 0.868 INCHES MINIMUM AND 0.882 INCHES MAXIMUM
CTZB CONTACT VOLTAGE RATING IN VOLTS 30.0 DC AT SEA LEVEL FOURTH VOLTAGE
AKBY TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
ABPM BODY DIAMETER 0.564 INCHES MINIMUM AND 0.571 INCHES MAXIMUM
AWTN OPERATING TEMP RATING -54.0 DEG FAHRENHEIT MINIMUM AND 300.0 DEG FAHRENHEIT MAXIMUM
ABKW OVERALL HEIGHT 0.760 INCHES NOMINAL
CTZB CONTACT VOLTAGE RATING IN VOLTS 250.0 AC AT SEA LEVEL FIRST VOLTAGE
CTHF CONTACT LOAD CURRENT RATING 1.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
CRLD NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
AXGY MOUNTING METHOD SLOT
CQYJ MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
STYL STYLE DESIGNATOR DISC W/FLANGE
ABTD MOUNTING SLOT WIDTH 0.151 INCHES MINIMUM AND 0.161 INCHES MAXIMUM

Similar Parts