Part Number
Part Number:
NSN:
NIIN:
Item Name:
REACTOR-TRANSFORMER
Definition:
A COMPONENT CONSISTING OF TWO OR MORE ELECTRICALLY DISTINCT ITEMS. ONE OR MORE ITEMS ARE MADE OF ONE OR MORE COILS WHICH FUNCTION AS A REACTOR; AT LEAST ONE OTHER ITEM IS MADE OF A TAPPED COIL OR TWO OR MORE COILS WHICH FUNCTION AS A TRANSFORMER. THE ITEMS MAY HAVE A COMMON CORE, BUT ARE NOT MAGNETICALLY COUPLED.
CAGE Information
Code | Company |
---|---|
11402 | HISONIC INC. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRGS | DC RESISTANCE RATING IN OHMS | 0.150 3RD COMPONENT SINGLE WINDING |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 2ND COMPONENT |
ACZB | FREQUENCY RATING | 10.0 KILOHERTZ NOMINAL 3RD COMPONENT |
AAJD | THREAD CLASS (NON-CORE) | 2B SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC POUNDS PER HOUR WET 2ND COMPONENT SINGLE PRIMARY |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AEHZ | MAXIMUM OPERATING TEMP | 55.0 DEG CELSIUS |
ASKA | COMPONENT NAME AND QUANTITY | 1 COIL AND 2 TRANSFORMER |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP 1ST COMPONENT ALL SECONDARY |
ABHY | TURN QUANTITY | 50 3RD COMPONENT SINGLE WINDING |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP 1ST COMPONENT SINGLE PRIMARY |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED AND BROUGHT OUT TO PRIMARY TERMINAL 2ND COMPONENT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.400 INCHES NOMINAL |
CQPZ | WINDING CONDUCTOR SIZE | 0.00795 INCHES AMERICAN WIRE GAGE 3RD COMPONENT SINGLE WINDING |
ADAQ | BODY LENGTH | 3.400 INCHES NOMINAL |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT SINGLE WINDING AND WINDING TURNS 3RD COMPONENT SINGLE WINDING |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 16.0 AMPERES NOMINAL B 2ND COMPONENT SINGLE PRIMARY |
ACZB | FREQUENCY RATING | 100.0 KILOHERTZ NOMINAL 1ST COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 7.70 AC POUNDS PER HOUR WET 1ST COMPONENT SINGLE PRIMARY |
ACZB | FREQUENCY RATING | 100.0 KILOHERTZ NOMINAL 2ND COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD CONNECTED TO SECONDARY TERMINAL 1ST COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP 2ND COMPONENT SINGLE PRIMARY |
CBBL | FEATURES PROVIDED | TINNED WIRE LEADS |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.900 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAT | BODY WIDTH | 2.000 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 18 WIRE LEAD |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 1ST COMPONENT AND 3 SECONDARY 1ST COMPONENT |
FEAT | SPECIAL FEATURES | 2ND COMPONENT,CURRENT TRANSFORMER,SECONDARY RATED BUT NOT INCLUDED |