Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
OSCILLOSCOPE

Definition:

A TEST INSTRUMENT WHICH IS DESIGNED TO GIVE VISUAL INDICATIONS ON A CATHODE RAY TUBE OF INSTANTANEOUS VALUES AND VARIATIONS IN ELECTRICAL VOLTAGE. IT CAN ALSO BE USED TO INDICATE ANY QUANTITY WHICH CAN BE CONVERTED INTO TERMS OF ELECTRICAL POTENTIAL. IT MAY INCLUDE AN INTEGRAL PULSE GENERATOR, THE OUTPUT OF WHICH CAN BE USED TO TRIGGER AN EXTERNAL COMPONENT; BE TRIGGERED BY PULSES FROM AN EXTERNAL SOURCE, OR IT MAY UTILIZE A SPECIAL TYPE OF MULTIGUN CATHODE RAY TUBE AND CIRCUITRY WHICH PERMITS A TRACE(S) TO BE SUSTAINED AND DISPLAYED INDEFINITELY, AND THE TRACE(S) MAY BE ERASED WHEN DESIRED. FOR ITEMS WHICH ARE NOT SEPARABLE AND OPERABLE WHEN DETACHED FROM EQUIPMENT OF WHICH THEY ARE A PART (BUILT INTO OPERATIONAL EQUIPMENT), SEE INDICATOR (2) (AS MODIFIED); MONITOR (AS MODIFIED); AND RECORDER (AS MODIFIED). SEE ALSO OSCILLOGRAPH.

CAGE Information

Code Company
80049 DEPARTMENT OF THE AIR FORCE

Federal Supply Class

Title

ELECTRICAL AND ELECTRONIC PROPER

Inclusions:

INCLUDES TEST LEADS AND TEST LEAD ATTACHMENTS; TEST INSTRUMENTS DESIGNED FOR COMMUNICATION EQUIPMENT; TEST INSTRUMENTS DESIGNED FOR USE WITH ELECTRONIC EQUIPMENT CLASSIFIED IN TWO OR MORE FSC GROUPS.

Exclusions:

EXCLUDES RADIAC EQUIPMENT

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
BHDP FREQUENCY RESPONSE RATING PROVIDED
BHDD AMPLIFIER DEFLECTION SENSITIVITY PROVISION PROVIDED
BHFT CAMERA RECORDING DEVICE ACCOMMODATION NOT PROVIDED
BGQK SCREEN SIZE 3 IN.
BHDT AMPLIFIER INPUT IMPEDANCE RATING PROVISION PROVIDED
BGQM GENERATOR DRIVEN FEATURE NOT INCLUDED
BGSD EXPANDED SWEEP NOT PROVIDED
BHDW X-AXIS INPUT IMPEDANCE RATING 10.0 MEGOHMS NOMINAL
BGQL SWEEP CIRCUITS INCLUDED
ABKW OVERALL HEIGHT 10.000 INCHES NOMINAL
ABMK OVERALL WIDTH 6.750 INCHES NOMINAL
BHFH TRACE STORAGE TUBE NOT INCLUDED
BHDL PLATE DIRECT CONNECTION DEFLECTION SENSITIVITY PROVISION NOT PROVIDED
ATES BEAM QUANTITY 1
AXGY MOUNTING METHOD PORTABLE
BGQQ SINGLE TRIGGER SWEEP DURATION 90.0 MICROSECONDS NOMINAL
BHFF CALIBRATED SCREEN SCALE NOT INCLUDED
FEAT SPECIAL FEATURES X-AXIS FREQUENCY RESPONSE RATING: DC TO 4 MC
ACZB FREQUENCY RATING 60.0 HERTZ NOMINAL
ABHP OVERALL LENGTH 17.000 INCHES NOMINAL
BGRZ TRIGGER SWEEP VOLTAGE AMPLITUDE RATING 150.0 VOLTS NOMINAL
BHDH INPUT INTENSITY MODULATION FEATURE NOT PROVIDED
BHDR Y-AXIS FREQUENCY RESPONSE RATING 2.0 HERTZ MINIMUM AND 3500000.0 HERTZ MAXIMUM
AMSE VOLTAGE RATING 105.0 VOLTS MINIMUM AND 125.0 VOLTS MAXIMUM
ACDC CURRENT TYPE AC
BHDF VERTICAL DEFLECTION SENSITIVITY VOLTAGE RATING 0.1 VOLTS MINIMUM RMS PER INCH AND 50.0 VOLTS MAXIMUM RMS PER INCH
BGQP SWEEP FREQUENCY RANGE +50.000/+800.000 HERTZ
FAAZ PHASE SINGLE
BHDG HORIZONTAL DEFLECTION SENSITIVITY VOLTAGE RATING 0.5 VOLTS CW OUTSIDE DIAMETER AND 500.0 VOLTS PEAK OUTSIDE DIAMETER
BGSB TRIGGER SWEEP POLARITY SWITCH INCLUDED

Similar Parts