Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
SWITCH , THERMOSTATIC

Definition:

A SWITCH THAT IS ACTUATED BY CHANGES IN AMBIENT TEMPERATURE. EXCLUDES CIRCUIT BREAKER; CONTROL, TEMPERATURE (AS MODIFIED); FUSE (AS MODIFIED); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; AND THERMOSTAT, FLOW CONTROL. SEE ALSO CONTROL, TEMPERATURE (AS MODIFIED) AND REGULATOR, TEMPERATURE (AS MODIFIED).

CAGE Information

Code Company
3B150 RAYTHEON TECHNICAL SERVICES COMPANY

Federal Supply Class

Title

SWITCHES

Inclusions:

INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.

Exclusions:

EXCLUDES SWITCHGEAR.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AFDT SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS 0.536 INCHES MINIMUM AND 0.546 INCHES MAXIMUM
AFDT SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS 0.536 INCHES MINIMUM AND 0.546 INCHES MAXIMUM
CTYC CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET
CTYS CONTACT ADJUSTMENT TYPE EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW
CQYJ MOUNTING FACILITY PATTERN ISOSCELES TRIANGLE
THSD THREAD SERIES DESIGNATOR UNC ALL THREADED HOLE
CTZB CONTACT VOLTAGE RATING IN VOLTS 115.0 AC AT SEA LEVEL SECOND VOLTAGE
AXGY MOUNTING METHOD FLANGE AND THREADED HOLE
CTHF CONTACT LOAD CURRENT RATING 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
AFDV LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS 0.827 INCHES MINIMUM AND 0.947 INCHES MAXIMUM
AFDS LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS 1.079 INCHES MINIMUM AND 1.085 INCHES MAXIMUM
ABHP OVERALL LENGTH 5.000 INCHES NOMINAL
CSCF TERMINAL TYPE WIRE LEAD
CQGB CONTACT ACTION STIMULUS INCREASE
MEDA MEDIA FOR WHICH DESIGNED GAS OR LIQUID
FEAT SPECIAL FEATURES ONE 1.750 IN. DIA MTG FLANGE SUPPLIED
CTHF CONTACT LOAD CURRENT RATING 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
STYL STYLE DESIGNATOR RECTANGULAR
ADAQ BODY LENGTH 3.531 INCHES NOMINAL
CTZB CONTACT VOLTAGE RATING IN VOLTS 230.0 AC AT SEA LEVEL FIRST VOLTAGE
AKBY TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
CTYX CONTACT STIMULUS RATING 350.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 340.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT
CMLP THREAD QUANTITY PER INCH 32 ALL THREADED HOLE
ABPM BODY DIAMETER 0.618 INCHES MINIMUM AND 0.625 INCHES MAXIMUM
CQJX NOMINAL THREAD SIZE 0.164 INCHES ALL THREADED HOLE
CRLD NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CTYM CONTACT ADJUSTMENT RANGE -50.00/+400.00 ACTUATION POINT DEGREES FAHRENHEIT AND -50.00/+400.00 DEACTUATION POINT DEGREES FAHRENHEIT
ABMK OVERALL WIDTH 0.625 INCHES NOMINAL

Similar Parts

271-1012P2 , 2711012P2 , 5930-00-296-4868 , 5930002964868 , 002964868