Part Number
Definition:
A COMPONENT WHICH CONVERTS AVAILABLE ALTERNATING CURRENT OR DIRECT CURRENT ELECTRICAL POWER INTO A FORM REQUIRED TO OPERATE ANOTHER COMPONENT OR SET. THE ITEM MAY CONSIST OF A COMBINATION OF AN INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; WITH A TRANSFORMER AND RECTIFIER(S) EMPLOYING ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE COMPONENTS, OR THE SYNCHRONIZED SECONDARY CONTACT(S) OF A VIBRATOR, SELF-RECTIFYING; OR MAY CONSIST OF ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE RECTIFIERS AND CAPACITORS IN TRANSFORMERLESS (ALTERNATING CURRENT-DIRECT CURRENT TYPE) CIRCUITS WHICH MAY BE OF THE VOLTAGE-MULTIPLIER TYPE. THE ITEM MAY INCORPORATE A FILTER, DIRECT CURRENT POWER AND PROVISIONS FOR REGULATION OF INPUT AND/OR OUTPUT VOLTAGE. THE ITEM MAY HAVE SPECIAL INPUT, OUTPUT, CONTROL OR OTHER FACILITIES FOR APPLICATIONS IN SPECIALIZED ENVIRONMENTS SUCH AS MEDICAL, DENTAL OR OTHER OPERATIONS. EXCLUDES BATTERY CHARGERS AND ROTATING MACHINERY TYPES OF ITEMS, SUCH AS MOTOR GENERATORS AND DYNAMOTORS.
CAGE Information
Code | Company |
---|---|
04655 | GENERAL DYNAMICS C4 SYSTEMS INC. |
Federal Supply Class
Title
CONVERTERS, ELECTRICAL, NONROTAT
Inclusions:
INCLUDES COMPLETE BATTERY CHARGING EQUIPMENT, NONROTATING; POWER SUPPLIES, MULTIAPPLICATION.
Exclusions:
EXCLUDES RECTIFYING TUBES; (FSC 5960); RECTIFYING CRYSTALS (FSC 5961); ROTATING EQUIPMENT (FSC 6125); TRANSFORMERS (FSC 5950); AND SEMICONDUCTOR DEVICES AND ASSOCIATED HARDWARE (FSC 5961).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CWHF | OUTPUT CONNECTION QUANTITY | 2 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT |
APNX | INPUT VOLTAGE RATING | 105.0 AC POUNDS PER HOUR DRY 2ND OPERATING POWER RQMT AND 127.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT SINGLE POWER OUTPUT |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ABHP | OVERALL LENGTH | 5.625 INCHES NOMINAL |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
BGHX | OUTPUT CONTROL QUANTITY | 1 SINGLE POWER OUTPUT |
APNX | INPUT VOLTAGE RATING | 210.0 AC POUNDS PER HOUR DRY 1ST OPERATING POWER RQMT AND 254.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST OPERATING POWER RQMT |
ABMK | OVERALL WIDTH | 4.875 INCHES NOMINAL |
CWGH | OUTPUT CURRENT RATING | 2.2 DC AMPERES MINIMUM SINGLE POWER OUTPUT AND 4.0 DC AMPERES MAXIMUM SINGLE POWER OUTPUT |
ABKW | OVERALL HEIGHT | 2.625 INCHES NOMINAL |