Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
21355 | LTA/D-CEMCO INC DBA D-CEMCO |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-P-18177,TYPE GEE MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
ABGT | BOARD THICKNESS | 0.062 INCHES |
ABCS | TERMINAL ROW QUANTITY | 1 |
PRMT | PRECIOUS MATERIAL | SILVER |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.156 INCHES |
PMLC | PRECIOUS MATERIAL AND LOCATION | TERMINAL SURFACE SILVER |
CRNL | NONFEEDTHRU TERMINAL TYPE | 433 SINGLE |
MATT | MATERIAL | GLASS FIBER BOARD AND PLASTIC EPOXY BOARD |
AAMA | MOUNTING HOLE DIAMETER | 0.144 INCHES |
AAQL | BODY STYLE | STRIP TYPE |
CWLN | TERMINAL DESIGN | NONFEEDTHRU |
CWLG | TERMINAL PATTERN ARRANGEMENT | SINGLE ROW |
ABDA | TERMINAL QUANTITY PER SECTION | 5 |
BWGP | SECTION QUANTITY | 5 |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 9.375 INCHES |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.250 INCHES |
SFTT | SURFACE TREATMENT | SILVER TERMINALS |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.156 INCHES |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 25 SINGLE |
ABGN | BOARD OVERALL LENGTH | 9.688 INCHES |
ABCX | BOARD CONSTRUCTION | SCORED FOR EASY BREAKING INTO SMALLER TERMINAL BOARDS |
ABGP | BOARD OVERALL WIDTH | 0.312 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |