Part Number
Definition:
AN ITEM CONSISTING OF A PARTIAL TURN AS ONE OR MORE TURNS OF WIRE OR OTHER CONDUCTIVE MATERIAL WHICH CONSTITUTES ONE CONTINUOUS UNTAPPED WINDING. IT MAY BE WOUND OR FORMED IN OTHER THAN A CIRCULAR MANNER AND MAY BE SELF-SUPPORTING, REQUIRING NO COIL FORM. IT IS SPECIFICALLY DESIGNED TO FURNISH INDUCTIVE REACTANCE IN A CIRCUIT CARRYING RADIO FREQUENCY CURRENT RANGING FROM 20 KILOHERTZ (KILOCYCLES) AND ABOVE. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). THE COIL HAS ONLY TWO ELECTRICAL TERMINALS. FOR ITEMS HAVING TAPPED WINDING OR MORE THAN ONE WINDING - SEE TRANSFORMER, RADIO FREQUENCY. FOR COILS WOUND ON RESISTORS, WHICH ARE DESIGNED TO BE INSERTED IN THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC.
CAGE Information
Code | Company |
---|---|
98095 | POWER DESIGNS INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAQ | BODY LENGTH | 1.688 INCHES NOMINAL |
CQPZ | WINDING CONDUCTOR SIZE | 0.02535 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE WINDING |
ABHY | TURN QUANTITY | 86 SINGLE COMPONENT SINGLE WINDING |
AXGY | MOUNTING METHOD | THREADED BUSHING SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
CRGS | DC RESISTANCE RATING IN OHMS | 2.100 SINGLE COMPONENT SINGLE WINDING |
ACZR | CORE CONSTRUCTION | POWDERED SINGLE COMPONENT |
AGAV | END ITEM IDENTIFICATION | GENERAL PURPOSE ELECTRONIC TEST EQUIPMENT GPETE; AIRCRAFT, EAGLE F-15; WHIDBEY ISLAND CLASS LSD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZU | ADJUSTMENT DEVICE DRIVE TYPE | SLOTTED SCREW SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 28 SINGLE GROUP |
CTHD | ADJUSTMENT METHOD AND QUANTITY | 1 ADJUSTABLE CAPACITOR SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 150.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE WINDING |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
ACYV | INDUCTANCE RATING | 100.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING |
AKNA | INCLOSURE TYPE | OPEN |
ABHP | OVERALL LENGTH | 2.126 INCHES NOMINAL |
ADAR | BODY OUTSIDE DIAMETER | 0.475 INCHES NOMINAL |
ACZP | COIL FORM TYPE | HOLLOW SINGLE COMPONENT |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING AND WINDING TURNS SINGLE COMPONENT SINGLE WINDING |