Part Number
Definition:
TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING OR SHIELD; EACH HAVING CHARACTERISTICS NOT COMPLETELY CONFORMING TO CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY OR CORD, ELECTRICAL. INCLUDES ITEMS HAVING THE COMBINED CHARACTERISTICS OF TWO OR MORE OF THE AFOREMENTIONED NAMES. REFERS TO BULK QUANTITIES ONLY; FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
05973 | CHAMPLAIN CABLE CORP SUB OF HUBER AN |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AMQN | CONDUCTOR QUANTITY | 2 |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
MATT | MATERIAL | PLASTIC FLUORINATED ETHYLENE PROPYLENE 10TH POSITION PRIMARY INSULATION ALL CONDUCTORS AND PLASTIC POLYIMIDE 10TH POSITION PRIMARY INSULATION ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC FLUORINATED ETHYLENE PROPYLENE 9TH POSITION PRIMARY INSULATION ALL CONDUCTORS AND PLASTIC POLYIMIDE 9TH POSITION PRIMARY INSULATION ALL CONDUCTORS |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 34 SINGLE CONDUCTOR |
ASGF | TRACER COLOR | BLUE FIRST TRACER SECOND CONDUCTOR |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 SINGLE CONDUCTOR |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B355 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
CXDC | ROUND CONDUCTOR SIZE | 22 AWG SINGLE CONDUCTOR |
FEAT | SPECIAL FEATURES | A GREEN COLOR BAND SHALL BE APPLIED TO BASIC WIRE EVERY 2 3/4 INCHES |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B355 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.115 INCHES NOMINAL |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 2 SINGLES |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | COPPER 16TH POSITION CONDUCTOR CABLE |
HUES | COLOR | WHITE 7TH POSITION CONDUCTOR CABLE |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC FLUORINATED ETHYLENE PROPYLENE 7TH POSITION CONDUCTOR CABLE AND PLASTIC POLYIMIDE 7TH POSITION CONDUCTOR CABLE |
MATT | MATERIAL | PLASTIC POLYIMIDE 6TH POSITION CONDUCTOR ALL CONDUCTORS |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B355 ASSN STD SINGLE TREATMENT RESPONSE 16TH POSITION CONDUCTOR CABLE |
SFTT | SURFACE TREATMENT | NICKEL CORE CONDUCTOR ALL CONDUCTORS |
HUES | COLOR | YELLOW 6TH POSITION CONDUCTOR ALL CONDUCTORS |
ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MODIFIED BY WHITE TOPCOAT ON JACKET AND GREEN COLOR BANDS ON BASIC WIRES |
SFTT | SURFACE TREATMENT | NICKEL 16TH POSITION CONDUCTOR CABLE |