Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
12793 | AQUA-CHEM INC CLEAVER-BROOKS DIV |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABTD | MOUNTING SLOT WIDTH | 0.438 INCHES NOMINAL SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 400.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
BFMF | COOLING METHOD | SELF-COOLED |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 2.0 KILOVOLT-AMPERE SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 3 SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
ADAQ | BODY LENGTH | 15.188 INCHES NOMINAL |
ADAU | BODY HEIGHT | 9.938 INCHES NOMINAL |
ADAT | BODY WIDTH | 8.875 INCHES NOMINAL |
ABTB | MOUNTING HOLE DIAMETER | 0.438 INCHES NOMINAL SINGLE GROUP |
AKNA | INCLOSURE TYPE | OPEN |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 7.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |