Definition:
A VALVE WITH A BOLT OR STEM THAT MAY BE MECHANICALLY ACTUATED TO TWO DIFFERENT POSITIONS BY ROTARY OR LINEAR MOTION. IN THE FIRST POSITION, THE VALVE DISK IS LOCATED AND LOCKED AGAINST THE SEAT PERMITTING NO FLUID FLOW THROUGH THE VALVE. IN THE SECOND POSITION, ONE SIDE OF THE VALVE DISK IS LOCATED AGAINST THE SEAT PERMITTING MOVEMENT OF THE DISK IN A MANNER THAT WILL ALLOW A FLOW OF FLUID IN ONE DIRECTION THROUGH THE VALVE. THE VALVE DISK MAY BE SPRING LOADED. IT MAY BE INLINE OR CARTRIDGE (MANIFOLD) DESIGN. SEE ALSO VALVE (1), LIFT-CHECK AND VALVE (1), STOP-LIFT-CHECK.
CAGE Information
Code | Company |
---|---|
80064 | NAVAL SHIP SYSTEMS COMMAND |
Federal Supply Class
Title
VALVES, NONPOWERED
Inclusions:
INCLUDES AUTOMATIC NONPOWERED VALVES; GATE, GLOBE, ANGLE, CHECK, AND RELIEF VALVES; COCKS.
Exclusions:
EXCLUDES FIRE HYDRANTS (FSC 4210); SPRINKLER HEADS (FSC 4210); VALVES SPECIFICALLY DESIGNED FOR USE WITH FIRE FIGHTING EQUIPMENT (FSC 4210); PLUMBING EQUIPMENT, AND THE LIKE (FSC 4540).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CBBL | FEATURES PROVIDED | BONNET PACKING |
MEDA | MEDIA FOR WHICH DESIGNED | WATER, FRESH SINGLE RESPONSE |
ADSR | BONNET TYPE | OUTSIDE SCREW-YOKE |
BBJX | MOUNTING POSITION | HORIZONTAL |
CWDL | RAISED FACE NOMINAL DIAMETER | 2.875 INCHES 1ST END |
ADST | BONNET ATTACHMENT METHOD | BOLTED |
ADZH | RENEWABLE SEAT RING TYPE | THREADED |
CWCD | NOMINAL OUTSIDE DIAMETER | 6.125 INCHES 1ST END |
ADQU | FLOW CONTROL DEVICE | DISK |
STYL | STYLE DESIGNATOR | STRAIGHT THRU W/OFFSET FLANGED ENDS |
CWCK | NOMINAL THICKNESS | 0.875 INCHES 1ST END |
AQLR | VALVE OPERATION METHOD | MANUAL |
AWLS | CONNECTION TYPE | FLANGE 1ST END |
CQGM | MAXIMUM OPERATING PRESSURE | 600.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
ACJN | OFFSET DISTANCE | 2.250 INCHES |
CCFG | VALVE SIZE | 1.500 INCHES |
CWDH | RAISED FACE NOMINAL HEIGHT | 0.250 INCHES 1ST END |
ARKN | FLANGE SHAPE | ROUND 1ST END |
ADSU | DISK LOADING METHOD | WEIGHT |
CWDF | FLANGE FACE DESIGN | RAISED STRAIGHT 1ST END |
CWCF | FACE TO FACE DISTANCE | 12.000 INCHES |