Part Number
Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER AUTOTRANSFORME
Definition:
A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
13850 | TECHNIPOWER LLC DBA INTEGRATED POWER |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
ABTB | MOUNTING HOLE DIAMETER | 0.265 INCHES NOMINAL SINGLE GROUP |
ADAV | OVERALL DIAMETER | 3.000 INCHES NOMINAL |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
ABHP | OVERALL LENGTH | 3.500 INCHES NOMINAL |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
TTQY | TERMINAL TYPE AND QUANTITY | 5 TURRET |
CWJS | WINDING OPERATING VOLTAGE | 0.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 140.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY INPUT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 350.0 HERTZ MINIMUM SINGLE COMPONENT AND 1.2 KILOHERTZ MAXIMUM SINGLE COMPONENT |
FEAT | SPECIAL FEATURES | ONE IN. LONG,SCREWDRIVER SLOTTED SHAFT WITHOUT DIAL OR KNOB |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |