Part Number
Part Number:
NSN:
NIIN:
Item Name:
WAVEGUIDE ASSEMBLY
Definition:
AN ITEM CONSISTING OF ONE OR MORE DEFINITE LENGTHS OF STRAIGHT OR FORMED, FLEXIBLE OR RIGID, PREFABRICATED HOLLOW TUBING OF CONDUCTIVE MATERIAL. THE TUBING HAS A PREDETERMINED CROSS SECTION AND IS DESIGNED TO GUIDE OR CONDUCT HIGH FREQUENCY ELECTROMAGNETIC ENERGY THROUGH ITS INTERIOR. ONE OR MORE ENDS ARE TERMINATED. MAY INCLUDE COMMON MOUNTING OF A SWITCH, WAVE GUIDE, A DUMMY LOAD, ELECTRICAL AND OTHER COMPONENTS SUCH AS WAVEGUIDE SECTION, CABLE TERMINAL CHAMBER AND THE LIKE. EXCLUDES COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; AND TUNER, WAVEGUIDE.
CAGE Information
Code | Company |
---|---|
93346 | SENSOR AND ANTENNA SYSTEMS, LANSDALE |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AHSX | FLANGE INSIDE WIDTH | 0.688 INCHES MINIMUM ALL FLANGES AND 0.694 INCHES MAXIMUM ALL FLANGES |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDE AND RELATED EQUIPMENT |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES FIRST CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE ALL FLANGES SECOND CONNECTION FACILITY |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.318 INCHES MINIMUM AND 0.324 INCHES MAXIMUM |
CTFD | WAVEGUIDE LENGTH | 3.750 INCHES NOMINAL |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.26 |
AHSF | FLANGE QUANTITY | 2 |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE ALL FLANGES THIRD CONNECTION FACILITY |
AHTR | FLANGE MANUFACTURER PART NUMBER (NON-CORE) | M39000/3-078 SECOND FLANGE |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.418 INCHES MINIMUM AND 0.424 INCHES MAXIMUM |
AHSE | TUBING MANUFACTURER PART NUMBER (NON-CORE) | M23351/4-037 SINGLE TUBING SEGMENT |
FEAT | SPECIAL FEATURES | POWER RATING 800 WATTS AVERAGE |
AHTR | FLANGE MANUFACTURER PART NUMBER (NON-CORE) | M39000/3-082 FIRST FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.0965 INCHES MAXIMUM ALL FLANGES SECOND CONNECTION FACILITY |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR DOUBLE RIDGED EXTERNAL, RECTANGULAR |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
CTCJ | FLANGE STYLE | CONTACT, DOUBLE RIDGE TYPE ALL FLANGES |
FLEX | FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.688 INCHES MINIMUM AND 0.694 INCHES MAXIMUM |
AHTD | FLANGE DEPTH | 0.235 INCHES MINIMUM ALL FLANGES AND 0.265 INCHES MAXIMUM ALL FLANGES |
STYL | STYLE DESIGNATOR | STRAIGHT TYPE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.360 INCHES MINIMUM ALL FLANGES AND 1.390 INCHES MAXIMUM ALL FLANGES |
AHSY | FLANGE INSIDE HEIGHT | 0.318 INCHES MINIMUM ALL FLANGES AND 0.324 INCHES MAXIMUM ALL FLANGES |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.788 INCHES MINIMUM AND 0.794 INCHES MAXIMUM |
MATT | MATERIAL | ALUMINUM ALLOY SINGLE TUBING SEGMENT AND FLANGE |
AHTX | INSERTION LOSS IN DECIBELS | 0.20 |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.0960 INCHES MINIMUM ALL FLANGES SECOND CONNECTION FACILITY AND 0.145 INCHES MINIMUM ALL FLANGES FIRST CONNECTION FACILITY AND 0.0937 INCHES MINIMUM ALL FLANGES THIRD CONNECTION FACILITY AND 0.148 INCHES MAXIMUM ALL FLANGES FIRST CONNECTION FACILITY |
AHSZ | FLANGE OUTSIDE WIDTH | 1.360 INCHES MINIMUM ALL FLANGES AND 1.390 INCHES MAXIMUM ALL FLANGES |
AFJN | FRAGILITY FACTOR (NON-CORE) | MODERATELY DELICATE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.0939 INCHES MAXIMUM ALL FLANGES THIRD CONNECTION FACILITY |