Part Number
Part Number:
NSN:
NIIN:
Item Name:
HEATER , FLUID , ELECTRIC
Definition:
A UNIT SPECIFICALLY DESIGNED FOR HEATING FLUID BY A DIRECT FIRED METHOD, UTILIZING ELECTRIC HEATING ELEMENT.
CAGE Information
Code | Company |
---|---|
74924 | INDUSTRIAL ENGINEERING AND EQUIPMENT |
Federal Supply Class
Title
SPACE AND WATER HEATING EQUIPMEN
Inclusions:
INCLUDES BOILERS, 15 POUNDS WSP AND UNDER (FOR BOILERS OVER 15 POUNDS WSP, SEE FSC 4410); DOMESTIC WATER STORAGE TANKS THROUGH 100 GALLON CAPACITY; FIREPLACE HEATERS; FURNACES; SPACE HEATERS; HEATING RADIATORS; IMMERSION HEATERS; WATER HEATERS, THROUGH 100 GALLON RECOVERY CAPACITY (FOR HEATERS OVER 100 GALLONS RECOVERY CAPACITY, SEE FSC 4410).
Exclusions:
EXCLUDES VEHICLE HEATERS; (FSC 2540); AIRCRAFT HEATERS (FSC 1660).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ARJA | PRESSURE RATING | 100.0 POUNDS PER SQUARE INCH |
ABHP | OVERALL LENGTH | 74.750 INCHES MINIMUM AND 75.750 INCHES MAXIMUM |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | LUBE OIL CIRCULATION HEATER FOR SUPERVISOR OF SHIPBUILDING |
AKYD | ACCESSORY COMPONENTS AND QUANTITY | PROCESS THERMOCOUPLE (TYPE J 0.750 INCH HUB OUTLET NOZZLE) 1; HIGH LIMIT THERMOCOUPLE (TYPE J 0.500 INCH NPT ATTACHED TO ELEMENT) 1 |
CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | 450.0 AC/DC |
BDWW | WATTAGE RATING | 60.000 KILOWATTS |
ADAV | OVERALL DIAMETER | 13.500 INCHES NOMINAL |
MATT | MATERIAL | STEEL CORROSION RESISTING AND GLASS FIBER |
FEAT | SPECIAL FEATURES | MAXIMUM OUTLET TEMP 160 DEG F;FLOW RATE 7 GPM; NEMA TYPE 4 TERMINAL ENCLOSURE; 3 PHASE; 2 CIRCUITS; HORIZONTAL FLOOR MOUNT; FLANGE TYPE HEATING ELEMENT |