National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
WORK STATION , CLEAN AIR , LAMINAR
Definition:
AN ASSEMBLY DESIGNED TO PRODUCE A PURIFIED, POSITIVE AIR FLOW IN A CONTROLLED AREA. THIS IS ACCOMPLISHED BY FILTERING AIR FROM OUTSIDE THE STATION AND CREATING A HIGHER (POSITIVE) PRESSURE INSIDE. THE LAMINAR INDICATES A STREAMLINE FLOW PAST AN OBJECT SO THAT THE VELOCITY AT ANY FIXED POINT IS CONSISTENT OR VARIES IN A REGULAR MANNER. EXCLUDES WORK STATION, CLEAN AIR, NON-LAMINAR.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
HF58E-590 | 16085 | A | 3 | 2 | 4 | SB |
CAGE Information
Code | Company |
---|---|
16085 | DEXON INC |
Federal Supply Class
Title
CLEAN WORK STATIONS, CONTROLLED
Inclusions:
INCLUDES LAMINAR AND NONLAMINAR FLOW ENCLOSURES; DUST CONTROLLED FACILITIES; AIR SHOWERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TEXT | GENERAL CHARACTERISTICS ITEM DESCRIPTION | HEPA FILTERS 99.99 PCT EFFICIENT; FRONT ACCESS TO PREFILTER; AIR FLOW 100 FPM PORM 10 PCT LAMINAR W/MIN INC OF TWICE THE ORIG RESISTANCE; LIGHTING WHITE FLUORESCENT; BLOWERS STATICALLY AND DYNAMICALLY BALANCED W/TRIAC SPEED CONTROL; 115 VAC,60 HZ,SINGLE PHASE,ELECTRICAL POWER; WD 98.4 IN.,WORK AREA HT 22.2,WT 82O LBS |